Instruction Manual

(4) RELIABILITY TEST METHOD
MECHANICAL
NO. ITEMS
1 Solderability test
Dipping: 245 ± 5 , 3 ± 1 seconds
2 lead tensile 1.0 Kg MIN. The lead of product is pulled with a load of
strength test 1.0kg mininum until lead breakdown. The tensile
force shall be recorded.
3 Vibration test
L/L±7%
The product is fixed ento the vibration with
Visual:OK
amplitude of 1.52m/m at a frequency of 1055Hz
sweeping for lmin. The vibration is done at X,Y,
Z direction respectively for 2 houes, totally 6
hours.
4 Soldering heat Visual:OK The leads of product are dipped into a solder pot
resistance test Circuit:OK
of 260±5 for a duration of 10±1sec. Nothing
particular on visual and open circuitry as a
result of ore testing.
ENVIRONMENTAL
NO. ITEMS
1 Humidity
L/L±5% The product is placed in a chamber of 40±2,
endurance
9095%RH for 96 hours. Measurement is done
test
after the reaovery of 424 hours.
2 High temp
L/L±5%
endurance test
3 Low temp test
L/L±5%
4 Thermal shock
L/L±5%
test
Page-3/4
MCD-1216-SERIES
This constitues one cycle. Ten cycles of such
testing shall be completed. Measurement is made
after recovery for 424 hours from the
completion of testing.
The specimens are placed in a chamber and the
temp is then lowered to -20±2 for one hour.
The temp will raised to +80±2 for one hour.
SPECIFICATIONS CONDITIONS
SPECIFICATIONS
The product is placed in a chamber of -40±2,
for 96 hours. Measurement is done after
recovery of 424 hours.
The product is placed in a chamber of 80±2,
for 72 hours. Measurement is done after recovery
of 424 hours.
CONDITIONS
More than 90% of the
termnial electrode
should be covered
with solder.
MAG.LAYERS