User manual

Confidential, the whole present document is the sole property of Maestro Wireless Solution Ltd.
76
21.1.3 Reading Counter Service
Enter AT+CSTRSTAT = “CT 1” will get Counter #1 info:
21.1.4 Reading Countdown Timer Service
Enter AT+CSTRSTAT = “TM 1” will get Countdown Timer #1 info:
21.1.5 Reading Input Pin Service
Enter AT+CSTRSTAT = “IP 1” will get Input Pin #1 info:
21.1.6 Reading Email Sending Service
Reading Enter AT+CSTRSTAT = “EM 1” will get Email set #1 info:
21.1.7 Reading Analogue Input Service
Reading Enter AT+CSTRSTAT = “AI 1” will get AI #1 info:
21.1.8 Reading Socket Communication Service
Reading Enter AT+CSTRSTAT = “SC 1” will get Socket Communication set #1 info:
CT 1 : ST 300 CV 20 TR 3
a b c d
a. Service id
b. trigger value of the counter
c. current value of the counter
d. Command String id to be executed if trigger (0 if
not to trigger)
TM 1 : CV 90 SW 0 TR 3
a b c d
a. Service id
b. current value of the timer
c. timer is running (1) or stop (0)
d. Command String id to be executed if trigger (0 if
not to trigger)
IP 1 : MS 1 DR 0 TH 5 TR 3
a b c d e
a. Service id
b. Mask value (valid for multiple I/P trigger)
c. direction of detection
d. threshold value of the detection
e. Command String id to be executed if trigger (0 if
not to trigger)
EM 1 : TO 1 CC 0 BC 5 SU 3 BD 1
a b c d e f
a. Service id
b. id of TO recipient
c. id of CC recipient
d. id of BC recipient
e. id of email subject
f. id of email body
AI 1 : TP 1 HL 100 LL 10 TH 5 TR 1 CV 30
a b c d e f g
a. Service id
b. Trigger Type (1-3)
c. High Limit (mV)
d. Low Limit (mV )
e. Threshold value (second)
f. Command String id to be executed if
trigger (0 if not to trigger)
g. current value (mV)
SC 1 : TO 1 BD 1
a b c
a. Service id
b. id of TO recipient
f. id of message body