Defined Values:
<oper>
Define type of operation:
0 store Command String to flash
1 read Command String from flash
2 erase Command String from flash
3 execute Command String stored in flash
<id>
Identification number (id) of the Command String. Valid value is 1 to 50, and 80; i.e.
up to 51 Command Strings can be stored.
Command String with id = 80 will be executed when modem power up
<string>
Command String
Note:
Each Command String is limited to 128 bytes.