Owner`s manual

39
Troubleshooting
In general, refer any service problems to your Mark Levinson dealer.
Before contacting your dealer, however, check to see if the problem is
listed here. If it is, try the suggested solutions. If none of these solves
the problem, contact your Mark Levinson dealer.
1. The Nº360 won’t function, and the Display is dark.
The standby button on the front panel isn’t turned on.
The Nº360 isn’t plugged into the AC mains.
The wall socket, adapter, or extension cord is faulty.
Theres a tripped circuit breaker or blown fuse in the
wall outlet’s circuit.
A fuse is blown in your Nº360 (contact your Mark
Levinson dealer).
2. The Display is Lit, but there is no output
The proper source isn’t selected on your Nº360.
The proper source isn’t selected on your preamplifier.
The interconnecting cables are connected incorrectly or
are faulty.
3. The Nº360 display reads “CD1 OFF.”
The selected digital source component for Input #1 is
turned off.
The digital connection between the digital source and
the Nº360 is faulty.
4. The linked functions don’t work.
The Link cable is disconnected, or is connected incor-
rectly.
The digital audio cable is disconnected, or is connected
incorrectly (in which case the Display Link function
would continue to work correctly, but none of the oth-
ers would work).
Try turning off/disconnecting AC power from both the
transport and the Nº360. After several seconds, restore
AC power to the digital processor, then turn on the
Nº31’s main power switch.
You may have older versions of the system software in
your associated Mark Levinson components which do
not fully support all Linked functions. Contact your
Mark Levinson dealer with the model and serial num-
bers of your Mark Levinson components. If needed,
new EPROMs will be provided at no charge.