TCTemp2000 Data Logger Manual Red 485 Dark Blue Pantone 289 Light Blue 58% of Pantone 289
Table of Contents MadgeTech TCTemp2000 Section 1: Device Safety............................................................................3 1.1 Model information....................................................................3 1.2 Specifications............................................................................3 1.3 Warranty...................................................................................5 Section 2: Device Overview.............................................................
MadgeTech TCTemp2000 6.7 Channel Statistics:...................................................................21 6.8 Type Statistics:.........................................................................21 6.9 Statistics Information Screen:...................................................22 6.10 Unit Selection Menu:.............................................................22 6.11 Device Configuration Menu:..................................................23 6.12 Adjust Visibility:..................
MadgeTech TCTemp2000 Section 1: Device Safety CAUTION: DEVICE MUST BE USED ONLY IN A MANNER CONSISTENT WITH THIS MANUAL. NOTICE: WHEN 230VAC SUPPLY USED, MADGETECH SPECIFIES USE OF AC SUPPLY PART # T35-9-100R-3 MANUFACTURED BY ENG ELECTRIC. THIS SUPPLY IS AVAILABLE FROM MADGETECH. 1.1 Model information • Model: TCTemp2000 • Description: Measure & record temperature on both an internal and an external probe channel with LCD display • Manufactured by MadgeTech, Inc. Warner, NH USA 1.
MadgeTech TCTemp2000 Dot-Matrix LCD Dimensions: 2.5” x 1.
MadgeTech TCTemp2000 Dimensions: 4.8” x 3.3” x 1.25” (122mm x 84mm x 32mm) Weight: 16 oz (440 g) Enclosure: Black anodized aluminum 1.3 Warranty Products manufactured by MadgeTech, Inc., are warranted against defective material and workmanship for a period of one year, starting from the date of shipment. In the event that a MadgeTech product is found to be defective, MadgeTech will repair or replace the product at its sole discretion. Such repair or replacement shall be the sole remedy of this warranty.
MadgeTech TCTemp2000 Section 2: Device Overview Power Jack LED Indicators Communication Jack LCD Display Screen Black anodized aluminum enclosure Page 6 Up Key Okay Key Down Key Function Keys Cancel Key
MadgeTech TCTemp2000 Section 3: Important Status Icons 3.1 Battery Status Full Empty Battery Battery Battery status icons indicate the state of charge of the batteries. When the battery empty indicator is displayed, the battery should be replaced. 3.2 Memory Status Memory Empty Memory Full The memory status icons indicate the amount of memory left for data storage. If the TCTemp2000 is in wraparound mode, the memory status icon will always indicate empty. 3.
MadgeTech TCTemp2000 3.4 Delay Start Indicator The delay start icon indicates that a logging operation is scheduled for the future. 3.5 Wait Icon The wait icon indicates that the device is busy. 3.6 Stop Icon Indicates that the TCTemp2000 is not currently taking readings. 3.7 External Power Icon Indicates that the TCTemp2000 is powered by an external source. 3.8 Reset Icon Indicates that the device has been reset.
MadgeTech TCTemp2000 Section 4: Front Panel Overview 4.1 Changing the display units The TCTemp2000 comes with factory default display units of °C for both the internal temperature and external probe channels. These units can be easily changed by pressing the F3 button in the main screen and then selecting either F1 for the internal temperature or F2 for external probe.
MadgeTech TCTemp2000 Large: Both channels can be displayed and take up entire available screen space. Button pressing chain: Main Screen -> F4 -> F1 -> F4 -> F2 repeatedly to scroll or UP and DOWN to scroll 4.3 Checking the memory Status A status icon appears on all screens representing memory, but further information including percent memory left and number of readings taken can also be viewed.
MadgeTech TCTemp2000 Section 5: TCTemp2000 Function Reference 5.1 Main Screen The main screen of the TCTemp2000 features a real-time display of most recently measured internal temperature and external probe data. At the bottom of the main screen are tabs corresponding to each of the four function keys. These tabs are used to access the four main function menus of the TCTemp2000: status, statistics, units, and setup.
MadgeTech TCTemp2000 5.2.iii Time The time screen displays current time data including the current time and date, time and date of last measured data, and current time zone. 5.3 Statistics Menu Pressing the F2 key while in the Main Screen brings up the Statistics Menu. From the Statistics Menu, statistics generated from the conditions encountered by the device can be viewed in a variety of different styles including being sorted by channel and by type.
MadgeTech TCTemp2000 5.4 Units Pressing the F3 key while viewing the Main Screen will access the Units Selection screen. Here the measurement units can be easily changed. In the Units Selection screen the F1 and F2 function keys correspond to the two channels internal temperature and external probe respectively.
MadgeTech TCTemp2000 that it will be shown. Channels can be toggled by either repeatedly pressing the channel’s corresponding function key or by using the UP and DOWN keys. 5.5.i.b Display Configuration By selecting “MORE” (either by pressing the F4 key on the Adjust Visibility Screen or by pressing the OK button) in the Display section the Display Configuration screen can be viewed. Here LCD screen contrast values can be set as well as the size the channels are displayed on the Main Screen.
MadgeTech TCTemp2000 Display The TCTemp2000’s LCD screen has options to be either on continuously or turn off automatically after 5 minutes of inactivity. This option can be changed by first pressing the F1 key to highlight the display parameter configuration tab. Once the tab is highlighted the option can be changed by pressing the F1 key repeatedly or using the UP and DOWN keys to select either “On” or “Auto”. Backlight Like the display, the LCD screen’s backlight also has power saving options.
MadgeTech TCTemp2000 5.5.ii.c Power Status Selecting “MORE” by either pressing the F4 key or the OK key while viewing the Display Update Mode screen brings up the Power Status screen. On this screen the battery type is displayed and should be changed by the user based on whether a Lithium or Alkaline battery is used in the TCTemp2000. This can be changed by first pressing the F1 button to highlight the type parameter configuration tab.
MadgeTech TCTemp2000 It is important to keep your device properly calibrated to ensure accurate readings. 5.5.iii.d Device Version Pressing the F4 key while viewing the Maximum or Minimum Device Range screens will display the Device Version screen, containing information such as firmware revision number and communications baud rate. Values on this screen cannot be modified. 5.5.iii.e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device Version screens.
MadgeTech TCTemp2000 Section 6: TCTemp2000 Screen Descriptions 6.1 Main Screen: Displays last measured values. F1 = STATUS: goes to status screens F2 = STATS: shows statistics menu F3 = UNITS: goes to unit selection screen F4 = SETUP: shows device configuration menu CANCEL = no function OK = no function UP = scrolls channel readings (only available while using large text) DOWN = scrolls channel readings (only available while using large text) 6.
MadgeTech TCTemp2000 OK = returns to main screen UP = no function DOWN = no function 6.3 Status Screens (Memory Status): Displays information about the device’s memory capabilities including percent of memory available (memory left), number of readings taken so far (readings), max number of readings (max readings), and wrap.
MadgeTech TCTemp2000 F3 = TIME: displays date and time screen F4 = MORE: displays ID parameters screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.5 ID Parameters Displays information relating to device identity. F1 = ID: no function F3 = MORE: displays the first status screen F4 = EXIT: returns to main screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.
MadgeTech TCTemp2000 OK = returns to main screen UP = no function DOWN = no function 6.7 Channel Statistics: Displays statistics (maximum recorded value, minimum recorded value, and average recorded value) based on channel (Internal Temperature or External Probe).
MadgeTech TCTemp2000 CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.9 Statistics Information Screen: Displays current statistics information including the number of recorded readings, start date, and start time. F1 = CLEAR: Gives the option to clear all statistics F2 = no function F3 = no function F4 = EXIT: returns to Statistics Menu CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.
MadgeTech TCTemp2000 repeatedly or using the UP and DOWN arrows to select appropriate units. CANCEL = returns to main menu without accepting changes OK = accepts changes and returns to main menu 6.11 Device Configuration Menu: Displays options available within the device configuration menu.
MadgeTech TCTemp2000 CANCEL = return to Display Configuration Menu OK = moves on to Display Configuration screen UP = once channel parameter configuration tab is highlighted scrolls through available options DOWN = once channel parameter configuration tab is highlighted scrolls through available options 6.13 Display Configuration: Allows the user to change the contrast of the LCD display as well as the channel size.
MadgeTech TCTemp2000 6.14 Power Modes Screen: Displays information regarding the devices different power modes including the display visibility, backlight options, and LED modes.
MadgeTech TCTemp2000 UP = once parameter configuration tab is highlighted scrolls through available options DOWN = once parameter configuration tab is highlighted scrolls through available options 6.16 Power Status Screen: Displays details about power available to the device including the battery type, battery voltage, and external voltage.
MadgeTech TCTemp2000 F4 = MORE: shows further Device Information screens CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.18 Device Information Screens (Maximum Device Range): Displays values indicating maximum internal temperature and external probe (for thermocouple selected) data detectable by the TCTemp2000. 6.19 Device Information Screens (Device Version): Displays device version information.
MadgeTech TCTemp2000 6.20 Device Information Screens (Firmware Version): Displays device firmware version information. F1 = VERS: shows Device Version screen F2 = FIRM: no function F3 = MORE: shows Device Range (Minimum) screen F4 = EXIT: Returns to Device Configuration Menu CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
MadgeTech TCTemp2000 6.22 Calibration Information Screens (Internal Temperature Calibration): Displays calibration information for internal temperature channel. F1 = DATE: shows calibration date information F2 = AMB: Shows ambient calibration information F3 = PROBE: shows external probe calibration information F4 = MORE: shows further calibration information screens CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
MadgeTech TCTemp2000 6.24 Device Reset Screen (Hardware Reset): Displayed as notification when a hardware reset has occurred.
MadgeTech TCTemp2000 6.25 Device Reset Screen (Power Interruption): Displayed as notification when power is interrupted during device operation.
MadgeTech TCTemp2000 Section 7: Computer Interface: Insert the USB connector of the IFC200 into an available USB port. Fully insert male connector of the IFC200 interface cable into the female receptacle of the data logger*. *WARNING: Install driver before connecting a device using a USB for the first time. See the Data Logger Software manual for further information.
MadgeTech TCTemp2000 Section 8: Wall Mounting Power Supply Cable Slot Page 33
MadgeTech TCTemp2000 Section 9: Maintenance BATTERY WARNING Most MadgeTech data loggers contain a lithium battery. Do not cut the battery open, incinerate, or recharge. Do not heat lithium batteries above the specified operating temperature.* Dispose of the battery in accordance with local regulations. *See the individual specification sheets at www.madgetech.com. The TCTemp2000 does not have any user-serviceable parts except the battery which should be replaced periodically.
MadgeTech TCTemp2000 Section 10: Terms and Conditions All products furnished by MadgeTech, Inc. (“Seller”) shall be in accordance with the following terms and conditions unless otherwise stated in writing: These Terms and Conditions (“Terms and Conditions”) govern (a) all sales quotations and sales of components, equipment, parts, and other products (“Product”) from, and (b) all service proposals and provisions of services by Seller to the buyer of the Products (“Buyer”).
MadgeTech TCTemp2000 CLAIMS ANY AND ALL OTHER REPRESENTATIONS AND WARRANTIES OF ANY KIND WHATSOEVER, WHETHER EXPRESSED, IMPLIED OR STATUTORY, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT OR ACCURACY, ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT, WITH RESPECT TO ANY OF THE SELLER MANUFACTURED PRODUCTS, CONSUMABLES OR SOFTWARE, OR ANY OF THE SELLER PROVIDED SERVICES.
6 Warner Road l Warner, NH 03278 Phone 603.456.2011 l Fax 603.456.2012 www.madgetech.com l info@madgetech.