User guide

RFPRHTemp2000A
Measurement Range -20 °C to +60 °C
Measurement Resolution 0.01 °C
Calibrated Accuracy ±0.5 °C (0 °C to +50 °C)
Temperature
Measurement Range 0 to 95 % RH non-condensing
Measurement Resolution 0.1 %RH
Calibrated Accuracy ±3 %RH
Humidity
Measurement Range 250 mbar to 1300 mbar
Measurement Resolution 0.02 mbar
Calibrated Accuracy ±10 mbar
Pressure
RF Frequency
2.45 GHz IEEE 802.15.4 ultra-low power MadgeNET wireless
transceiver with fully bi-directional communication
Band
ISM band 2.405-2.475 GHz
Operation (channels 11 through 25) @ 250 kbps
Maximum Output Power +0 dBm typical
Receiver Sensitivity
(RFC1000)
-95 dBm typical
Transmission Distance
(to other RFC1000s)
RFC1000
4,000’ max. outdoors - line of sight unobstructed
1,000’ max. indoors - typical urban environment
RFC1000-CE
2,500’ max. outdoors - line of sight unobstructed
700’ max. indoors - typical urban environment
RFC1000-IP69K
4,000’ max. outdoors - line of sight unobstructed
1,000’ max. indoors - typical urban environment
Transmission Distance
(to data loggers)
RFC1000, RFC1000-CE & RFC1000-IP69K
2,000’ max. outdoors - line of sight unobstructed
500’ max. indoors - typical urban environment
Wireless
Battery Warning
WARNING: BATTERY MAY LEAK, FLAME OR EXPLODE IF DISASSEMBLED, SHORTED, CHARGED, CONNECTED
TOGETHER, MIXED WITH USED OR OTHER BATTERIES, AND/OR EXPOSED TO FIRE/HIGH TEMPERATURE.
DISCARD USED BATTERY PROMPTLY, KEEP OUT OF REACH OF CHILDREN.
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
7