Manual
Table Of Contents
- Macurco_CD-12xx_Manual(REV. A)
- 1 GENERAL SAFETY INFORMATION
- 2 USER INSTRUCTIONS AND LIMITATIONS
- 3 INSTALLATION AND OPERATING INSTRUCTIONS
- 3.1 Location
- 3.2 General Wiring Information
- 3.3 Mains Power Connection
- 3.4 Fan Relay Connection
- 3.5 Alarm Relay Connection
- 3.6 4-20mA Signal Connection
- 3.7 Installation
- 3.8 Power Up
- 3.9 Operation
- 3.10 Default Configuration – Factory Settings
- 3.10.1 Selecting Default Configuration – “dEF”
- 3.10.2 Selecting Power Up Test Option – “PUt”
- 3.10.3 Selecting Display Option – “dSP”
- 3.10.4 Selecting Buzzer Option – “bUZ”
- 3.10.5 Selecting Alarm Relay Setting – “ArS”
- 3.10.6 Selecting Alarm Relay Configuration – “Arc”
- 3.10.7 Selecting Fan Relay Settings – “FrS”
- 3.10.8 Selecting Fan Relay Delay – “Frd”
- 3.10.9 Selecting Fan Relay Minimum Runtime – “Frr”
- 3.10.10 Selecting Fan Relay Latching Option – “FrL”
- 3.10.11 Selecting Trouble Fan Setting Option – “tFS”
- 3.10.12 Selecting 4-20mA Output Option – “420”
- 3.11 Onboard Diagnostics
- 4 Maintenance
- 5 Appendix A – Menu Structure
- 6 MACURCO PRODUCTS LIMITED WARRANTY
- Macurco_CD-12xx_Manual(REV. A)Canadian_French
- 1 INFORMATIONS GÉNÉRALES DE SÉCURITÉ
- 2 INSTRUCTIONS ET LIMITES D'UTILISATION
- 3 INSTRUCTONS D’INSTALLATION ET D'UTILISATION
- 3.1 Emplacement
- 3.2 Informations générales de câblage
- 3.3 Raccordement de l’alimentation principal
- 3.4 Raccordement du relais de ventilateur
- 3.5 Raccordement du relais d'alarme
- 3.6 Raccordement du signal 4-20 mA
- 3.7 Installation
- 3.7.1 Diagramme pour un courant d'alimentation du relais de commande du ventilateur compris entre 4 et 20 mA
- 3.7.2 Raccordement de base au réseau électrique d'une pièce
- 3.7.3 Raccordement du détecteur à un tableau d'alarme
- 3.7.4 Raccordements de dispositifs CD-12 en cascade
- 3.7.5 Câblage du panneau de contrôle DVP-120
- 3.7.6 Branchement alternatif sur tableau de commande
- 3.8 Mettre en marche
- 3.9 Opération
- 3.10 Configuration par défaut - Paramètres usine
- 3.10.1 Sélection configuration par défaut - "dEF"
- 3.10.2 Sélection d’option de démarrage Test - "PUt"
- 3.10.3 Sélection d’option d'affichage - "dSP"
- 3.10.4 Sélection d’option alarme - "bUZ"
- 3.10.5 Sélection réglage du relais d'alarme – "ArS"
- 3.10.6 Sélection de configuration du Relais Alarme - "Arc"
- 3.10.7 Sélection des paramètres de relais ventilateur - "FrS"
- 3.10.8 Sélection de relais ventilateur retardé - "Frd"
- 3.10.9 Sélection relais de ventilateur d'exécution - "Frr"
- 3.10.10 Sélection de relais de ventilateur, option de verrouillage - "FrL"
- 3.10.11 Sélection de ventilateur de condition de trouble option - "tFS"
- 3.10.12 Sélection 4-20mA Option de sortie - "420"
- 3.11 Systèmes de diagnostic
- 4 Entretien
- 5 Annexe A – Structure de menu
- 6 GARANTIE LIMITÉE DES PRODUITS MACURCO
- Macurco_CD-12xx_Manual(REV. A)Spanish
- 1 Información general de seguridad
- 2 Instrucciones y limitaciones del usuario
- 3 Instrucciones de instalación y funcionamiento
- 3.1 Ubicación
- 3.2 Información general del cableado
- 3.3 Conexión de alimentación de red
- 3.4 Conexión del relé del ventilador
- 3.5 Conexión de relé de alarma
- 3.6 conexión de la señal 4-20mA
- 3.7 Instalación
- 3.8 Encendido
- 3.9 Operación
- 3.10 Configuración predeterminada: configuración de fábrica
- 3.10.1 Seleccionando Configuración predeterminada – "Def”
- 3.10.2 Selección de la opción de prueba de encendido – "Poner”
- 3.10.3 Selección de la opción de visualización – "DSP”
- 3.10.4 Selección de la opción zumbador – "Buz”
- 3.10.5 Selección del ajuste del relé de alarma – "ARS”
- 3.10.6 Selección de la configuración de relé de alarma – "Arc"
- 3.10.7 Selección de los ajustes del relé del ventilador – "FRS”
- 3.10.8 Selección del retardo del relé del ventilador – "FRD”
- 3.10.9 Selección de la duración mínima del relé del ventilador – "FRR”
- 3.10.10 Selección de la opción de bloqueo del relé del ventilador – "FRL”
- 3.10.11 Selección de problemas opción de ajuste del ventilador – "TFS”
- 3.10.12 Selección de la opción de salida 4-20mA-"420"
- 3.11 Diagnóstico a bordo
- 4 Mantenimiento
- 5 Apéndice A – estructura del menú
- 6 Garantía limitada de productos MACURCO
4
2 USER INSTRUCTIONS AND LIMITATIONS
WARNING
Each person using this equipment must read and understand the information in these User Instructions before use. Use of this equipment by
untrained or unqualified persons or use that is not in accordance with these User Instructions, may adversely affect product performance and
result in sickness or death.
2.1 Use For
The CD-12”x” provides CO
2
detection and automatic ventilation control for conference rooms, classrooms, meeting halls or similar
applications. Carbon dioxide is a colorless, odorless gas that is produced both by people exhaling CO
2
as well the burning of gasoline,
coal, oil, and wood. The outdoor concentration of carbon dioxide can vary from 350-450 parts per million (ppm) or higher in areas with
high vehicle traffic or industrial activity. The indoor CO
2
level depends upon the number of people present, how long an area has been
occupied, the amount of outdoor fresh air entering the area and other factors. CO
2
concentrations indoors can vary several hundred
parts per million in areas with many people present for an extended period and where fresh air ventilation is limited. Outdoor "fresh" air
ventilation is important as it can dilute CO
2
levels of the indoor environment. The amount of fresh air that should be supplied to a room
depends on the type of facility and room. Ventilation should keep carbon dioxide concentrations below 1000 ppm and create indoor air
quality conditions that are acceptable to most individuals.
For applications storing or using CO
2
tanks, the detector will provide notification in the event of a gas leak. Such applications include but
are not limited to food storage, beverage dispensing, agriculture, fire suppression, medical, etc.
The CD-12H uses an automated background calibration program to set the clean air level on a regular basis. The CD-12H will maintain
accuracy if it is exposed to the “clean air reference value” (this reference value is the lowest concentration to which the sensor is exposed)
at least once per week.
The CD-12MC does not perform automated background calibrations and it is suggested to perform a Manual Calibration on the unit no
less than once per year using the Macurco CD6-FCK calibration kit.
Note:
This applies when used in typical indoor ambient air. The CD-12”x” can be used as a standalone detector. For use with the Macurco Detection
and Ventilation Control Panel (DVP-120 only), and other fire/security panels or building automation systems. Line voltage is provided to the CD-12”x”
with the 4-20mA communication loop connected back to the panel.
WARNING
Use only for monitoring the gas which the sensor and instrument are designed to monitor. Failure to do so may result in exposures to gases
not detectable and cause sickness or death. For proper use, see supervisor or User Instructions, or call Technical Support at 844-325-3050.
2.2 Do Not Use For
The CD-12”x” is not intended for use in hazardous locations or industrial applications such as refineries, chemical plants, etc. Do not
mount
the CD-12”x” where the normal ambient temperature is below 32°F or exceeds 122°F (0°C or above 50°C). The CD-12”x” mounts on a
type 4S electrical box supplied by the contractor. Do not install the CD-12”x” inside another box unless it has good air flow through it.
WARNING
This equipment may not function effectively below 32°F or above 122°F (0°C or above 50°C). Using the detector outside of this temperature
range may adversely affect product performance and result in sickness or death.
2.3 General Description
The CD-12H is a line voltage, dual relay Carbon Dioxide (CO
2
) detector, and automatic ventilation controller. The CD-12”x” uses a
microcomputer controlled, electronic system to measure the concentration of CO
2
, actuate relays and provide a 4-20 mA output. The
CD-12”x” has a low maintenance long life (15+ years) non-dispersive infrared (NDIR) sensor and optional gas test/calibration kits. The
CD-12”x” is a low-level meter capable of displaying from 0-5000 ppm of carbon dioxide.