Manual
Table Of Contents
- Macurco_CD-12xx_Manual(REV. A)
- 1 GENERAL SAFETY INFORMATION
- 2 USER INSTRUCTIONS AND LIMITATIONS
- 3 INSTALLATION AND OPERATING INSTRUCTIONS
- 3.1 Location
- 3.2 General Wiring Information
- 3.3 Mains Power Connection
- 3.4 Fan Relay Connection
- 3.5 Alarm Relay Connection
- 3.6 4-20mA Signal Connection
- 3.7 Installation
- 3.8 Power Up
- 3.9 Operation
- 3.10 Default Configuration – Factory Settings
- 3.10.1 Selecting Default Configuration – “dEF”
- 3.10.2 Selecting Power Up Test Option – “PUt”
- 3.10.3 Selecting Display Option – “dSP”
- 3.10.4 Selecting Buzzer Option – “bUZ”
- 3.10.5 Selecting Alarm Relay Setting – “ArS”
- 3.10.6 Selecting Alarm Relay Configuration – “Arc”
- 3.10.7 Selecting Fan Relay Settings – “FrS”
- 3.10.8 Selecting Fan Relay Delay – “Frd”
- 3.10.9 Selecting Fan Relay Minimum Runtime – “Frr”
- 3.10.10 Selecting Fan Relay Latching Option – “FrL”
- 3.10.11 Selecting Trouble Fan Setting Option – “tFS”
- 3.10.12 Selecting 4-20mA Output Option – “420”
- 3.11 Onboard Diagnostics
- 4 Maintenance
- 5 Appendix A – Menu Structure
- 6 MACURCO PRODUCTS LIMITED WARRANTY
- Macurco_CD-12xx_Manual(REV. A)Canadian_French
- 1 INFORMATIONS GÉNÉRALES DE SÉCURITÉ
- 2 INSTRUCTIONS ET LIMITES D'UTILISATION
- 3 INSTRUCTONS D’INSTALLATION ET D'UTILISATION
- 3.1 Emplacement
- 3.2 Informations générales de câblage
- 3.3 Raccordement de l’alimentation principal
- 3.4 Raccordement du relais de ventilateur
- 3.5 Raccordement du relais d'alarme
- 3.6 Raccordement du signal 4-20 mA
- 3.7 Installation
- 3.7.1 Diagramme pour un courant d'alimentation du relais de commande du ventilateur compris entre 4 et 20 mA
- 3.7.2 Raccordement de base au réseau électrique d'une pièce
- 3.7.3 Raccordement du détecteur à un tableau d'alarme
- 3.7.4 Raccordements de dispositifs CD-12 en cascade
- 3.7.5 Câblage du panneau de contrôle DVP-120
- 3.7.6 Branchement alternatif sur tableau de commande
- 3.8 Mettre en marche
- 3.9 Opération
- 3.10 Configuration par défaut - Paramètres usine
- 3.10.1 Sélection configuration par défaut - "dEF"
- 3.10.2 Sélection d’option de démarrage Test - "PUt"
- 3.10.3 Sélection d’option d'affichage - "dSP"
- 3.10.4 Sélection d’option alarme - "bUZ"
- 3.10.5 Sélection réglage du relais d'alarme – "ArS"
- 3.10.6 Sélection de configuration du Relais Alarme - "Arc"
- 3.10.7 Sélection des paramètres de relais ventilateur - "FrS"
- 3.10.8 Sélection de relais ventilateur retardé - "Frd"
- 3.10.9 Sélection relais de ventilateur d'exécution - "Frr"
- 3.10.10 Sélection de relais de ventilateur, option de verrouillage - "FrL"
- 3.10.11 Sélection de ventilateur de condition de trouble option - "tFS"
- 3.10.12 Sélection 4-20mA Option de sortie - "420"
- 3.11 Systèmes de diagnostic
- 4 Entretien
- 5 Annexe A – Structure de menu
- 6 GARANTIE LIMITÉE DES PRODUITS MACURCO
- Macurco_CD-12xx_Manual(REV. A)Spanish
- 1 Información general de seguridad
- 2 Instrucciones y limitaciones del usuario
- 3 Instrucciones de instalación y funcionamiento
- 3.1 Ubicación
- 3.2 Información general del cableado
- 3.3 Conexión de alimentación de red
- 3.4 Conexión del relé del ventilador
- 3.5 Conexión de relé de alarma
- 3.6 conexión de la señal 4-20mA
- 3.7 Instalación
- 3.8 Encendido
- 3.9 Operación
- 3.10 Configuración predeterminada: configuración de fábrica
- 3.10.1 Seleccionando Configuración predeterminada – "Def”
- 3.10.2 Selección de la opción de prueba de encendido – "Poner”
- 3.10.3 Selección de la opción de visualización – "DSP”
- 3.10.4 Selección de la opción zumbador – "Buz”
- 3.10.5 Selección del ajuste del relé de alarma – "ARS”
- 3.10.6 Selección de la configuración de relé de alarma – "Arc"
- 3.10.7 Selección de los ajustes del relé del ventilador – "FRS”
- 3.10.8 Selección del retardo del relé del ventilador – "FRD”
- 3.10.9 Selección de la duración mínima del relé del ventilador – "FRR”
- 3.10.10 Selección de la opción de bloqueo del relé del ventilador – "FRL”
- 3.10.11 Selección de problemas opción de ajuste del ventilador – "TFS”
- 3.10.12 Selección de la opción de salida 4-20mA-"420"
- 3.11 Diagnóstico a bordo
- 4 Mantenimiento
- 5 Apéndice A – estructura del menú
- 6 Garantía limitada de productos MACURCO
15
All CD-12”x” units are factory calibrated and 100% tested for proper operation. During normal operation, the green status indicator LED
light will be on steady, the fan & alarm relay will be in standby mode and the 4-20 mA output will be at 4mA (in clean air). The unit also
performs a regular automatic self-test during normal operation. If the unit detects an improper voltage or inoperable component, it will
default into Error mode. In this error mode, the Alarm relay will be activated, the 4-20 mA current loop will go to 24 mA, the unit will
display the error code, the green status indicator LED light will flash, and the buzzer will chirp intermittently. The Fan relay will also
engage if the Trouble Fan Setting Option is set to “ON”.
4.3.1 Operation Test
Check that the green CD-12”x” status indicator LED light is illuminated continuously. If not, do not proceed with the tests. If the unit is in
error mode, contact your local representative or Macurco technical support representative for information on resolving the problem.
1. Remove the single screw in the middle of the front cover of the CD-12”x”.
2. Remove the front cover.
3. Observe the LED light on the front of the CD-12”x”.
4. If the light is solid green proceed to step 6.
5. If the green status indicator LED light is off or flashing, refer to the General section above.
6. Locate the switch labeled ENTER/TEST on the left side of the printed circuit board. Press the Test switch once.
7. The CD-12”x” will step through a cycle test:
a. The display progresses through the BUZ (Buzzer Test), Art (alarm relay test), Frt (fan relay test) then 42t (4-20 mA
output test). Make sure that the settings are “on” or not disabled “diS”.
b. During the first 10 seconds of the test cycle, the display will show BUZ and set off the audible buzzer
c. The alarm relay will be closed, so any devices connected to that relay will be tested.
d. The Fan relay will be activated for the next 1 minute of the test, so if the fan circuits are wired in the normal manner,
the fan should run.
e. The 4-20mA output will then ramp up from 4 to 16 mA over the next 130 seconds of the test, so if the circuit is wired
in the normal manner, the control panel or building automation system should respond.
f. At the end of the test cycle, the light will turn green and be on steady (Normal Operation), the fan & alarm relay will
be in standby mode and the 4-20 mA output will return to 4 mA (in clean air).
8. When testing is completed reassemble the unit or units.
4.3.2 Manual Operation Test
This option gives the user the opportunity to manually initiate an individual test for each relay, the analog output and the sensor response
to gas.
From normal operation mode press the Next button 2 times to get to the Test Mode (tSt).
Press the Enter button once to get into the Test Menu.
Press the Next button to scroll through the five test options and press Enter to initiate the selected test.
Note that if the relay or 4–20 mA output has been disabled, the test selection will not be displayed in the test menu.
bUZ- Buzzer Test, 3 seconds
Art - Alarm Relay Test, 5 seconds
Frt - Fan Relay Test, 60 seconds
42t - 420 loop test, 25 seconds
gtS - Gas Test, 3 minutes (no output to the panel during the gas test)
The display will flash during the test, or in the case of the gas test, the gas level will alternate with gtS. Once the test is complete, the
display will return to the steady display. To exit the test menu, press the Next button until “End” is displayed then, press Enter to return
to
normal mode.