Technical data
88
158.
2 D Electrophoresis System, Cleaver Bioscience UK
A) VS 10C2DS Complete Mini 2-D System Comprising
1x omniPAGE Mini Vertical Unit which includes: 2x2mm thick
Notched glass plates, 2x2mm thick plain glass plate with 1mm
Thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 12 samples),
1x casting base, silicon mat, cooling pack,
Plus: 1x Capillary electrophoresis module which includes : internal running module for tube gels, Capillary tubes, blanking plugd,2-
D combs and Spacers.
B) VS 20C2DS Complete Maxi 2-D System Comprising
1x omniPAGE Maxi Vertical Unit which includes: 2x4mm thick , Notched glass plates, 2x4mm thick plain glass plate with 1mm
Thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 24 samples), 1x casting base, silicon mat, cooling pack.
Plus: 1x Capillary electrophoresis module which includes : internal running module for tube gels, Capillary tubes, blanking plugd,2-
D combs and Spacers.
C) VS 10WC2DS Complete Mini Wide 2-D System Comprising
1x omniPAGE Mini wideVertical Unit which includes: 2x4mm thick, Notched glass plates, 2x4mm thick plain glass plate with
1mm , Thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 24 samples),
1x casting base, silicon mat, cooling pack, Plus: 1x Capillary electrophoresis module which includes : internal running module for
tube gels, Capillary tubes, blanking plugd,2-D combs and Spacers.
OR
With power pack ATTO, Japan. AE 6210 Slab gel cast (13.8 x 13 cm), including gel casting unit, Dual Slab Chamber, dummy
plate SAE 8450 power station etc. complete
OR
Technosource, India
A) Vertical Gel Apparatus
• Model- MICROKIN-(BD) :Cat. No.- 02-00143
(Ready to use system for bi-directional migration). The single sided unit includes an anodic tank (for in situ gel casting) and a
cathodic tank, both fitted with connectors and electrodes (for bi-directional migration); a lid; notched and rectangular glass plates
(gel size: L= 7.5 x W = 8.5 cm); two 1.5 mm thick slotted spacers; a PTFE comb (1.5 mm thick, 10-well, calculated vol. 75 µL /
well); a set of clamps; an agarose dispenser; a gel – sandwich opener; a pair of connecting cords and an instruction manual.
• Model- MICROKIN :Cat. No.- 01-00000 (Ready to use system for uni-directional migration).
A variable size (length, width and thickness) multiple sandwich gel electrophoresis apparatus with in situ casting. Includes a vented
lid; a central electrode unit with two male connectors and polarized current flow; a tank; four 1.5 mm slotted spacers; two matched
12 well PTFE combs; two notched and two rectangular glass plates (13 x 14 cm); a glass plates stand; an agarose dispenser; a gel-
sandwich opener; two buffer savers; a pair of connecting cords and an instruction manual.
B) Horizontal Gel electrophoresis apparatus
• Model – SLEEKSUB : Cat No.08-00102, Model SLEEKSUB (Ready to use system for DNA and protein separations.)
Unit will include lid; tank (buffer capacity about 300mL) with opaque platform, connectors and electrodes ( for uni directional
migration); a tray of gel gripping design and a UV- transparent base (gel size 7 (w) x 10 cm); a niche cleaner; a comb stand (comb-
height adjustable); a comb (10 well, 1.5 mm thick); connecting cords and an instruction manual
• Model – SLEEKSUB –R
Cat No. 08-00105
(Ready to use system for nucleic acid and protein separations).
Unit fabricated to exhibit greater resistance to cleaning reagents used in RNA analysis. System will include lid; tank (buffer capacity
about300mL) with opaque platform, connectors and electrodes (for uni directional migration); a tray of gel- gripping design and a
UV- transparent base (gel size 7 (w) x10 cm); a niche cleaner; a comb of connecting cords and an instruction manual