Technical data

68
127.
Distillation Unit For Oil
Extraction
SOCS PLUS AUTOMATIC SOLVENT EXTRACTION SYSTEM FOR OIL EXTRACTION
Alternative 1:
TWO PLACE AUTOMATIC SOLVENT EXTRACTION SYSTEM. MODEL SCS 2
Samples Two, Heater source Casted Aluminium Alloy heaters, Heater power 1000 W, Temperature Range
35ºC to 200ºC, Temperature Accuracy - +/- C of set temperature, Temperature Indication Digital, Temperature
Controller - PID Micro Controller with Auto Tuning facility, Temperature setting Feather Touch Membrane keys,
Extraction vessel Glass, Collection vessel 100 ml glass beaker, Extraction thimble nitro cellulose (25 X 80 mm),
Thimble Adoptor, Thimble Stand, Independent sample loading with individual controls, electrical requirement
230v,50Hz, AC Mains. Safety Features: Auto Over Temperature Protection, Auto Sensor Break protection, Auto
Error Indication, etc. Quote for Additional One set Beaker and Thimble Box
Alternative 2:
FOUR PLACE AUTOMATIC SOLVENT EXTRACTION SYSTEM. MODEL SCS 4
Samples Four, Heater source Casted Aluminium Alloy heaters, Heater power 2000 W, Temperature Range
35ºC to 200ºC, Temperature Accuracy - +/- C of set temperature, Temperature Indication Digital, Temperature
Controller - PID Micro Controller with Auto Tuning facility, Temperature setting Feather Touch Membrane keys,
Extraction vessel Glass, Collection vessel 100 ml glass beaker, Extraction thimble nitro cellulose (25 X 80 mm),
Thimble Adoptor, Thimble Stand, Independent sample loading with individual controls, electrical requirement
230v,50Hz, AC Mains. Safety Features: Auto Over Temperature Protection, Auto Sensor Break protection, Auto
Error Indication, etc Quote for Additional One set Beaker and Thimble Box
Alternative 3:
SIX PLACE AUTOMATIC SOLVENT EXTRACTION SYSTEM. MODEL SCS 6
Samples Six, Heater source Casted Aluminium Alloy heaters, Heater power 3000 W, Temperature Range
35ºC to 200ºC, Temperature Accuracy - +/- C of set temperature, Temperature Indication Digital, Temperature
Controller - PID Micro Controller with Auto Tuning facility, Temperature setting Feather Touch Membrane keys,
Extraction vessel Glass, Collection vessel 100 ml glass beaker, Extraction thimble nitro cellulose (25 X 80 mm),
Thimble Adoptor, Thimble Stand, Independent sample loading with individual controls, electrical requirement
230v,50Hz, AC Mains. Safety Features: Auto Over Temperature Protection, Auto Sensor Break protection, Auto
Error Indication, etc. Quote for Additional One set Beaker and Thimble Box