The following formula can be used by referencing the following flow table and product graph..
Q
= Flow rate (GPM)
Ps = Differential pressure (signal) through the test points of the valve (psi)
Cvs = Flow coefficient through the test points of the valve (GPM/psi )
Q
= Flow Rate (GPM)
P = Differential pressure (pressure loss) across the valve (psi)
Cv = Flow through valve (GPM @ 1psi pressure drop )
SVS
pCQ =
p
Q
C
V
=
Flow Rate
Pressure Loss
Model MS - FLOW MEASUREMENT
0 . 1
1
1 0
1 0 1 0 0 1 0 0 0 1 0 0 0 0
Q = F L OW RA T E [ GPM]
_
p
s
=
S
I
G
N
A
L
[
p
s
i
]
2 1 / 2 "
3 "
4 "
5 "
6 "
8 "
1 0 "
1 2 "
Q = Flowrate (GPM)
Ps = Si
g
nal (PSI)
Size Cvs Cv
2-1/2” 102 175.4
3” 142.2 261.6
4” 249.3 426.3
6” 389.5 654.2
6” 530.2 901.4
8” 929.4 1635.9
10” 1444 2497.2
12” 2122.6 3693.7
1/2
Submittal Data
Model MS
Optional features and accessories available
for this Macon product are an extra charge,
and not included in the standard model price.
Tunstall Corporation
118 Exchange Street
Chicopee, MA 01013
Form # MS-03.14