User Manual

Group28
EngineControlModule(ECM)DiagnosticTrouble
Codes(DTCs)
FMI4
Voltagebelow
normal,orshorted
tolowsource
CircuitshortedMILilluminatedFaultyharness
Faultyconnector
AftertreatmentDEFlineheater1or3
failure
AftertreatmentDEFpumpassembly
failure
AftertreatmentDEFtankheatingvalve
failure
AftertreatmentControlModule(ACM)
FMI5
Currentbelow
normaloropen
circuit
OpencircuitMILilluminatedFaultyharness
Faultyconnector
AftertreatmentDEFlineheater1or3
failure
AftertreatmentDEFpumpassembly
failure
AftertreatmentDEFtankheatingvalve
failure
AftertreatmentControlModule(ACM)
ECMSPN3675,EngineTurbochargerCompressorBypassValvePosition
MID128PPID330
Typeof
fault:
FMIDescription:
FaultCondition:
Possible
Symptoms:
PossibleCause:
FMI3
Voltageabove
normal,orshorted
tohighsource
Circuitshorted+
On/offvalvecan’t
beactivated
MILilluminated
Yellowelectronic
malfunctionlamp
illuminated
Regenerationnot
possible
Highengine
brakingwithout
request
Driveability
affected
Faultybypassvalvesolenoid
Faultyharness
Faultyharnessconnector
FMI4
Voltagebelow
normal,orshorted
tolowsource
Shortcircuit-
Valveconstantly
activated
MILilluminated
Yellowelectronic
malfunctionlamp
illuminated
Majorengine
derate
Exhaustmanifold
overheating
Engineshutdown
Faultybypassvalvesolenoid
Faultyharness
Faultyharnessconnector
75