User Manual

Group28
EngineControlModule(ECM)DiagnosticTrouble
Codes(DTCs)
FMI5
Currentbelow
normaloropen
circuit
Shorttobatteryon
themeteringside
ofthecircuit
Openinthe
meteringsideof
thecircuit
Openinthe
groundsideof
thecircuit
MILilluminatedFaultyharness
Faultysensor
Aftertreatmentcontrolmodule(ACM)
FMI15
Datavalidbutabove
normaloperating
range-Leastsevere
level
Temperature
sensorisoutof
range(high)
Sensorindicatesa
invalidvalue
MILilluminatedFaultyharness
Faultysensor
ECMSPN3249,AftertreatmentDPFIntakeTemperatureMID128PPID
387
Typeof
fault:
FMIDescription:
FaultCondition:
Possible
Symptoms:
PossibleCause:
FMI2
Dataerratic,
intermittentor
incorrect
Sensoris
notrational
(plausibility)
MILilluminated
Aborted
regeneration
Faultyharness
Faultyharnessconnectorsor
connections
Exhaustsystemleak
Faultysensor
FMI4
Voltagebelow
normal,orshorted
tolowsource
Shorttogroundon
themeteringside
ofthecircuit
MILilluminated
Aborted
regeneration
Faultyharness
Faultysensor
Aftertreatmentcontrolmodule(ACM)
FMI5
Currentbelow
normaloropen
circuit
Shorttobatteryon
themeteringside
ofthecircuit
Openinthe
meteringsideof
thecircuit
Openinthe
groundsideof
thecircuit
MILilluminated
Regenerationnot
possible
Faultyharness
Faultysensor
Aftertreatmentcontrolmodule(ACM)
FMI15
Datavalidbutabove
normaloperating
range-Leastsevere
level
Temperature
sensorisoutof
range(high)
Sensorindicatesa
invalidvalue
MILilluminatedFaultyharness
Faultysensor
58