User Manual

Group28
EngineControlModule(ECM)DiagnosticTrouble
Codes(DTCs)
ECMSPN639,SAEJ1939DataLink1MID128SID231
Typeof
fault:
FMIDescription:
FaultCondition:
Possible
Symptoms:
PossibleCause:
FMI2
Dataerratic,
intermittentor
incorrect
SAEJ1939highor
lowcircuitshorted
+
SAEJ1939highor
lowcircuitshorted
SAEJ1939high
orlowcircuitopen
MILilluminatedFaultyharnessorconnector
ECMSPN641,EngineVariableGeometryTurbocharger(VGT)Actuator
1MID128SID27
Typeof
fault:
FMIDescription:
FaultCondition:
Possible
Symptoms:
PossibleCause:
FMI0
Datavalidbutabove
normaloperational
range-Mostsevere
level
EngineVariable
Geometry
Turbocharger
(VGT)actuator
temperatureoutof
range
PossibleRed
engineshutdown
lampilluminated
(dependanton
severity)
Yellowelectronic
malfunctionlamp
illuminated
Possibleengine
derate
N/A
FMI2
Dataerratic,
intermittentor
incorrect
EngineVariable
Geometry
Turbocharger
(VGT)actuator
hasnotseena
validcommandon
CAN2datalink
Incorrectdata
MILilluminated
Yellowelectronic
malfunctionlamp
illuminated
Lowboost
Lowpower
Nozzleopens
Smokefrom
engine
DisturbanceonCAN2datalink
FMI4
Voltagebelow
normal,orshorted
tolowsource
ShorttogroundMILilluminated
Yellowelectronic
malfunctionlamp
illuminated
Nozzlewillopen
resultinginlow
powerandlow
boost
VGTactuator
willcontinue
toattemptand
maintaintarget
nozzleposition
FaultyVGTactuatorconnector
FaultyVGTactuatorharness
Lowbatteryvoltage
37