Temperature measurement sensor
accuracy
+/- 1°C
Temperature
Range: -40°C to + 60°C
Precision: +/- 1°C
Humidity
Absolute accuracy tolerance: +/- 3 %RH over
20..80%RH at 25°C
5 Installing the Bridge
The product is designed to be installed in almost any enviroment, some of
which include; Offices, hallways, closets, kitchens, bathrooms. The Bridge
should be mounted to the ceiling using the mounting bracket. And included
accessories.
5.1 Power Source
1. Power source is identified
2. If using wall outlet, install PoE Injector
a. PoE injector must be dressed at power source location
3. Install raceway from PoE Injector location to ceiling
Note: This product is intended to be supplied by a UL Listed Power
Supply Unit marked "Class 2" or "LPS" or "PS2" and rated 24-48 VDC,
0.5-1.0A (for PoE Input) 5VD, 0.5A (for micro USB)“.
5.2 Bridge ‘1’ in chain
1. ‘PoE In’ is supplied to install location
2. Bridge Mounting Bracket is installed based on ceiling layout
3. PoE from power source is connected to ‘Input’ on Bridge
4. Connect ‘PoE Out’ to ‘Output’
5. Latch Bridge onto Mounting Bracket via twisting it onto the
locked position.
6. Confirm power by LED activation
7. Confirm Bridge jointed the network by Solid Blue LED
8. Proceed with activation process through Asset Track app (Step 4)
9.
NOTE: For 1
st
Bridge in chain, Installer must ensure that jumpers are set
5.3 Bridge ‘2’ in chain
1. Connect Bridge 1 ‘PoE Out’ to Bridge 2 ‘Input’
2. Proceed with mounting process as described in Step 2.