SD125E Safety Information WARNING ¾ NEVER connect the transceiver to an AC outlet. This may pose a fire hazard or result in an electric shock. ¾ NEVER operate the radio transmitter without a suitable artificial load or antenna connected ¾ DO NOT allows children to operate transmitter-equipped radio equipment. CAUTION ¾ DO NOT operates the transceiver near unshielded electrical blasting caps or in an explosive atmosphere unless it is a type especially designed and qualified for such use.
SD125E Table of Contents Safety Information ................................................................................................................2 Table of Contents .................................................................................................................3 About your SD125E Series data radio......................................................................................4 About Your SD125E Radio .........................................................................
SD125E About your SD125E Series data radio About Your SD125E Radio The MaxonCIC SD-125E Series of RF Link Modules from MaxonCIC utilizes the latest technology in its design and manufacturing. Both the UHF and VHF models are PLL (Phase Lock Loop Synthesizer) /microprocessor controlled, and offer one to five watts of power with 16 channel capability.
SD125E General SD125E Specification General specification Equipment Type Model Series Performance Specifications Frequency Range RF Output Channel Spacing Modulation Type Intermediate Frequency Number of Channels Frequency Source Operation Rating External Power Supply Temperature Range VHF UHF Data radio (Wireless Data radio (Wireless Modem) Modem) SD-125E V2 SD-125E U2 TIA/EIA-603 /ETS 300-113 146-174MHz 440-470MHz 1-5W 1-5W 12.5KHz, 25KHz Programmable F3D, F3E 45.
SD125E SD125E Transmitter Specification Transmitter specification Model Series Carrier Power (Nom. Max. Min.) Hi Power Low Power Sustained Transmission Time 5 10 30Sec (Nominal Conditions) Frequency Error Nominal condition Extreme condition Frequency Deviation 25 KHz Channel Spacing 12.5 KHz Channel Spacing Audio Frequency Response Adjacent Channel Power 25 KHz Channel Spacing 12.5 KHz Channel Spacing Conducted Spurious Emission Modulation Sensitivity Hum & Noise : 25 KHz Channel Spacing 12.
SD125E SD125E Receiver Specification Receiver Specification VHF UHF Model Series SD-125E V2 SD-125E U2 < 0.28uV < 0.30uV < 0.28uV < 0.30uV < -113dBm < -110dBm > -3dB , < +3dB < -113dBm < -110dBm > -3dB , < +3dB Sensitivity (@ 12dB SINAD) 25 KHz Channel Spacing 12.5 KHz Channel Spacing Sensitivity ( 1/100 Error Rate) With ACC-513 With ACC-514 Amplitude Characteristic Adjacent Channel Selectivity 25 KHz Channel Spacing(Nom.) (Extreme Condition) 12.5 KHz Channel Spacing(Nom.
Unpacking Information Remove and carefully inspect the contents of your package(s) for the following items: 1. Radio 2. User Manual * If any items are missing or damaged please contact your Dealer or Maxon SD125E Features Synthesized Operation with 16 channel capability 1 / 5 Watt programmable output power Programmable 12.5 / 25 KHz channel spacing Busy channel lockout 16 channel TX Time-out timer Power Save FFSK Modem FSK Modem Frequency steps 6.25KHz, 5.00KHz and 2.
SD125E Description of Radio Components 1) Antenna connector 2) DB-09 connector 3) Top cover 4) DIP-S/W channel selector 5) Jumper selector Exterior View Antenna installation Fasten the antenna to the radio by turning the antenna cable clockwise onto the BNC receptacle on left of radio when looking at front of radio.
SD125E SD125E Series Operation 16 Channel select Your radio’s channel can be selected by inner DIP-S/W or serial command inputted from external control system. To change channel by inner DIP-S/W (4), you should open the upper cover and then look for the DIP-S/W (4) on the digital board of the bottom cover. Once located change the DIP-S/W to select wanted channel according to channel dip switch chart (See page 11).
SD125E Channel Selection Setting of channel selector switch for each channel Channel selector switch SW401 Page 11 English User Manual
SD125E Features Channel Spacing The SD-125E is capable of programmable channel spacing, in both UHF and VHF bands. Each channel can be programmed via the PC programmer, ACC-900E, having 12.5 KHz or 25 KHz channel spacing. Output Power RF Power is programmable in the SD-125E. Each channel can be programmed via the PC programmer to a high-power output, 5 Watts, or low-power output, 1 Watt. Busy Channel Lockout Busy Channel Lockout – ON: Upon PTT enable, if carrier is present, the radio will not transmit.
SD125E Serial Command Serial RX/TX Data Format (1) (2) (3) (4) (5) Asynchronous Serial Data Transfer Baud Rate : 4,800 bit/sec Data Bit : 8bit , Non Parity Stop Bit : 1bit MSB first transmission Each serial command consists of 3 bytes. 1st byte is command and 2nd is data required by command and 3rd is check sum to decide validity of total contents.
SD125E Audible alert tones Your SD-125E series data radio has a sophisticated microprocessor control which provides a range of audible tone.
User Manual SD125E SD125E Series This product is marked with in accordance with the Class II product requirement specified in the R&TTE Directive 1999/5/EC.
User Manual SD125E Maxon House, Cleveland Road, Hemel Hempstead, Hertfordshire, United Kingdom, HP2 7EY Tel: + 44 (0) 1442 267 777 Fax: + 44 (0) 1442 215 515 info@maxoncic.co.uk www.maxoncic.co.