User Manual
  SECTION 6 OPERATION  
169000 / 169040  33  Revision E 
6.6 HEADER ATTACHMENT: SELF-
PROPELLED 
Refer to your Self-Propelled Windrower 
Operator’s Manual for procedures for 
mechanically attaching the auger header to the 
self-propelled windrower, and for modifications if 
required to the windrower hydraulic connections. 
Refer to the following procedures for electrical 
and hydraulic connections. Header drive 
hydraulic hoses and electrical harness are 
located on the LH cab-forward side of the 
windrower. 
6.6.1 A30-S 
6.6.1.1  M100, M105, M150, M200 M155 
The M100, M105, M150, and M155 Windrowers 
are factory-equipped with A30-S header 
hydraulics and electrical harness. Proceed as 
follows: 
DANGER 
Stop engine, and remove key from ignition 
before leaving Operator's seat for any 
reason. A child or even a pet could engage 
an idling machine. 
a. Disengage rubber latch (A), and open driveline 
shield (B). 
b.  Remove the cap (C) from electrical connector, 
and remove connector from support bracket. 
c.  Disengage and rotate lever (D) counterclockwise 
to fully up position to release the hose bundle 
(E). 
d.  Move hose bundle (E) to header. 
e.  Rotate lever (D) clockwise, and engage in 
bracket to store. 
IMPORTANT 
If the hose bundle contains four hoses 
(draper header operation), only three are 
required to power the A30-S header.  
Ensure loose hose is properly secured to 
avoid contact with the drivelines. 
(continued next page) 
A 
B 
D
E
NOT USED 
D
C
E