User Manual
  SECTION 7 MAINTENANCE AND SERVICING 
169000 / 169040  159  Revision E 
7.13 CONDITIONER 
CAUTION 
To avoid personal injury, before servicing 
header/mower conditioner or opening drive 
covers, follow procedures in Section 7.1 
PREPARATION FOR SERVICING. 
7.13.1  Changing Gearbox Oil 
 NOTE 
Change conditioner drive gearbox 
lubricant after the first 50 hours of 
operation,  and  every  1000  hours 
(or 3 years) thereafter. 
a.  Lower header to ground. 
b.  Open driveline shield. 
c.  Place a suitable container under gearbox drain 
to collect oil. 
d. Remove breather (A), check plug (B), and drain 
plug (C). 
e.  Allow oil to drain. 
f.  Replace drain plug (C), and add oil at (A) to 
required level. Use Gear Lubricant,  
SAE 85W-140, API Service Class GL-5,  
1.06 quarts (1.0 liters). 
g.  Oil is at required level when it runs out of check 
plug (B). 
7.13.2  Forming Shield Removal 
a.  Remove hairpins (D), and washers that secure 
straps (E) to frame. 
b.  Hold onto forming shield, and slip straps off pins. 
Lower forming shield to ground. 
c.  Remove two clevis pins (F) from forming shield 
forward end. 
d. Lift forming shield off bolts (G) in windrower 
legs, and lower to ground. Replace clevis pins 
in forming shield. 
e.  Slide forming shield out from under windrower, 
or drive windrower away from forming shield. 
E
D
B 
A
C 
F 
G