User Manual
  SECTION 7 MAINTENANCE AND SERVICING 
169000 / 169040  139  Revision E 
7.8.12  Sickle Drive Timing Adjustment 
Double knife A30-D and A40-D Auger Headers 
require that the sickles are properly timed to 
move in opposite directions. 
CAUTION 
Stop engine, and remove key from ignition 
before leaving Operator's seat for any 
reason. A child or even a pet could engage 
an idling machine. 
a.  Remove the right side sickle drive belt. Refer to 
Section 7.8.10.5 Removal: RH Sickle Drive 
Timing Belt: - A30-D, or Section 7.8.11.5 
Removal: RH Sickle Drive Belt - A40-D. 
b.  Rotate LH side sickle drive box driven pulley (A) 
clockwise
 until LH side sickle (B) is at the center 
of the inboard stoke (moving towards center of 
header). 
NOTE 
Center stroke is when the sickle 
sections are centered between guard 
points as shown. 
c. Rotate right side sickle drive box pulley (C) 
counterclockwise
 until right side sickle (D) is at 
the center of the inboard stroke. 
d.  Install right side sickle drive box drive belt and 
tension. Refer to Section 7.8.10.6 Installation: 
RH Sickle Drive Belt - A30-D, or 7.8.11.6 
Installation: RH Sickle Drive Belt - A40-D. 
IMPORTANT 
To maintain timing, sickle drive box driver 
and driven pulleys must not rotate as the 
belt is tightened. 
e.  Check that timing belts are properly seated in 
the grooves on both driver and driven pulleys. 
f.  Check for correct sickle timing by rotating 
driveshaft (E) slowly with the unplug wrench (F), 
and observe sickles where they overlap at the 
center of the header. 
IMPORTANT 
Sickles must move in opposite directions, 
and must begin moving at exactly the 
same time. 
(continued next page) 
F
E
RIGHT
SICKLE
LEFT 
SICKLE 
DIRECTION OF 
MOVEMENT 
SECTIONS CENTERED 
BETWEEN GUARDS 
B 
D
A 
C 