Owner manual
Form # 147459  Issue 11/06 Web Rev_01 
116 
  TROUBLE SHOOTING 
SYMPTOM
PROBLEM 
SOLUTION 
REF. 
Air conditioning not 
producing sufficient 
cooling (continued). 
Clogged expansion 
valve. 
Recover system 
refrigerant and replace 
valve. Then, evacuate 
and charge system. 
* 
Clogged receiver-drier. 
Recover system 
refrigerant and replace 
receiver-drier. Then 
evacuate and charge 
system. 
* 
Excessive moisture in 
system. 
Recover system 
refrigerant and replace 
receiver-drier. Then 
evacuate and charge 
system. 
* 
Air in system. 
Recover refrigerant, 
evacuate and charge 
system. 
* 
Thermostat defective or 
improperly adjusted. 
Replace thermostat. 
* 
Blower motor sluggish 
in operation. 
Remove motor for 
service/replacement. 
* 
Air conditioning system 
too noisy. 
Defective winding or 
improper connection in 
compressor clutch coil 
or relay. 
Repair or replace as 
necessary. 
* 
Loose or excessively 
worn drive belt. 
Tighten or replace as 
required. 
66 
Noisy clutch. 
Remove clutch for serv-
ice or replacement as 
required. 
* 
Noisy compressor. 
Check mountings and 
repair. Remove 
compressor for service 
or replacement. 
* 
Compressor oil level 
low. 
Add SP-15 PAG refrig-
erant oil. 
* 
Blower fan noisy due to 
excessive wear. 
Remove blower motor 
for service or replace-
ment as necessary. 
* 
Excessive charge in 
system. 
Discharge excess 
refrigerant until pressure 
drops within specs. 
(Always recover 
discharged refrigerant.) 
* 
Low charge in system. 
Check system for leaks, 
charge system. 
* See your Windrower dealer. 