Owner manual
Form # 147069 Issue 09/06
41
ASSEMBLY
Preparing the Adapter (cont’d.)
5. Install pump in storage position at slot in right
hand float spring support and secure with lynch
pin at (L).
CAUTION: Wear gloves when handling
pump.
CHECK DECK DEFLECTOR POSITION
NOTE: Side deflectors (A) are factory set for an opening width (distance between deflectors (A), to correspond
to the feeder house opening for a specific model of combine, according to the following chart.
The rear vertical edge of deflectors (A) should just fit inside feeder house opening. If factory setting is not
correct for your model of combine, loosen bolts (C) (five per side) and adjust rear of deflector to suit feeder
house opening.
* Measured at height of bracket (D).
COMBINE MAKE & MODEL
REAR
DEFLECTORS
OPENING WIDTH*
Case 60 & 66 Series 36.6” (930 mm)
Case 77, 80 & 88 Series 46.5” (1180 mm)
Case AFX 49.2” (1250 mm)
JD 50 Series (except 9650) & Contour
Master (9500, 9510, CTS & CTS II)
55.9” (1420 mm)
JD 9600, 9610, 9650 59” (1500 mm)
New Holland CR 920/940/960 36.6” (930 mm)
New Holland CR 970/980 49.2” (1250 mm)
New Holland CX 59” (1500 mm)
Lexion 450, 460R, 470, 470R, 475, 560,
560R, 570R, 575R, 580 & 580R
49.2” (1250 mm)
Lexion 460, 465, 480, 480R, 485, 485R &
590R
59” (1500 mm)
Gleaner 39.4” (1000 mm)
Challenger 660, Massey Ferguson 9690 44.1” (1120 mm)
Challenger 670, Massey Ferguson 9790 55.1” (1400 mm)
L
STORE PUMP ON ADAPTER FRAME
A
SIDE DEFLECTORS
C
C
D