User's Manual
Setting the Rate of Fire (ROF) - LED Colour Green
Your Droid can electronically limit its maximum ROF. This is required in some
tournaments or elds. In uncapped modes, the ROF will only be limited by the
speed of the gun and hopper. If you use a capped mode (like PSP or Millenni-
um), the mode will obey the maximum ROF. The ROF is adjustable from 11bps
in 1/4bps increments (1=11, 2=11.25, 3=11.5 ... 26=uncapped).
Setting the Loader Delay
This is a small dwell included to allow the ball to settle into your marker breach
before ring. For a very fast loader, this may be set to 1, for slow hoppers it
should be higher. If your loader delay is set too low for your loader, then you may experience paintballs
breaking in the Droid breech.
Setting the Anti Mechanical Bounce (AMB)
Primarily, you should use the Debounce register to remove bounce from your Droid marker. However, if
you experience excessive bounce, it may be from a mechanical source. This AMB lter is designed to
remove excessive bounce, and it should be incremented slowly to remove bounce when bounce cannot
be removed using the Debounce register.
Setting the Anti Bolt Stick (ABS)
When your marker is idle for long periods, friction and settling effects can cause your bolt or other mov-
ing parts to be sticky. The ABS system is used to overcome this on the rst shot by temporarily increas-
ing the dwell setting. The ABS is adjustable from 1-10ms where the setting is the temporary increase in
dwell, and a setting of 1 removes the ABS completely.
Setting the Ramp Start
When using a ramp mode, this setting can be used to set the re rate at which ramping starts – adjust-
able from 4-14bps. Current PSP rules require a minimum setting of 5bps, whilst current Millennium