User's Manual
Programming Your Cyborg
To program the board, turn the gun off. Hold down the trigger whilst turning the
gun on. The indicator light will turn white, continue to hold the trigger until it goes
blue (debounce register). Press the trigger once to advance to the next setting as
given below. When you have a setting you would like to change, hold the trigger
until the indicator light goes out. Release the trigger, and the indicator light will
ash to show the current setting. Then when it goes out, input the new setting by
the trigger and wait for the indicator light to go solid again. The settings are:
Register Settings
Debounce (Blue) – Increase this setting to remove trigger bounce from the
marker. To remove trigger bounce, increase this slowly.
Dwell (Red) – Adjustment for the solenoid on time. This should be set to 6 or 7,
do not use other settings unless you are an advanced user.
Fire mode (White) – use this to set the gun to different re modes. Always
observe the rules in the locality in which you are playing. Note: ramping or
modes other than semi are not permitted in some countries. If you have pur-
chased your Cyborg within a country with restricted remodes, you will nd the
modes removed.
Max ROF (Green) – in uncapped modes, the ROF will only be limited by the
speed of the gun and hopper. However, if you use a capped mode (like PSP or
Millenium), the mode will obey this max ROF. The ROF is adjustable from 14bps
to unlimited in 1/4bps increments (1=14, 2=14.25, 3=14.5, 4=14.75, 5=15 …
26=uncapped).
Loader Delay (Yellow) – This is a small dwell included to allow the ball to settle
into your marker breach before ring. For a very fast hopper, this may be set to
1, for slow hoppers it should be higher.
Anti Mechanical Bounce (Teal) – This is a parameter used to remove mechani-
cal bounce (causing multiple shots). To remove mechanical bounce, increase
this slowly.
Anti Bolt Stick (Purple) – if your marker has sticking o-rings or parts, this set-
ting can increase the dwell temporarily if your marker has been sitting around.
1-10ms, setting 1 is off.
Ramp Start (Flickering Blue) – When using a ramp mode, this setting can be
used to set the re rate at which ramping starts – adjustable from 4-14bps
(default 5).
6
11
Gladiator (High Pressure Regulator - HPR)
Your Gladiator is a very hard wearing and reliable regulator. Regularly clean and lubri-
cate the piston and piston bore, as
well as the retainer o-rings using Dow
33. Also ensure that the seat face is
clean and free from damage.
You do not need to remove the
sleeve or seat assembly for main-
tenance, simply screw the Gladia-
tor in half, and set the bottom half
aside. Push the piston and retainers
out of the regulator by pushing from
the top with a large allen key. You
now have access to the Piston bore,
piston and retainer O-rings. Clean,
relube and re-assemble. Before the
screw the bottom back on, wipe the
seat face clean.
After performing maintenance on
your inline regulator, ensure that the
top and bottom sections are rmly
screwed back together.