User guide

1514
Unit installation and configuration/Main menuUnit installation and configuration/Main menu
Restoring factory settings
6) Locate and select the option FACtORy SEt-
tINGS to restore the factory settings of the
unit.
Select the option DELEtE to delete all the modi-
cations entered in the conguration by the installer
or operator of the unit.
Setting the signals
NOTE
The unit can switch the input signals; alter their brightness, contrast and satura-
tion conditions; and adjust the output carrier in RF.
1) Locate and select the option SEttINGS.
Configuring the input signals
1) Locate and select the option INPut.
a) Locate and select the option CH1:*****
BRIGHtNESS to check the type of input
signal, the video and audio detection, and
congure the brightness of the video signal
(1 to 255).
b) Locate and select the option CONt1
SAtuRAtION to congure the contrast
and saturation of video signal 1 (1 to 255).
c) Locate and select the option VOL. INPut
1 to congure the attenuation of audio
signal 1 in dB (1 to 40)
d) Locate and select the option SHARPNESS
1 to congure the sharpness of video sig-
nal 1 (HIGH, mEDIum SOFt or NONE).
e) Locate and select the option CODING 1.
This congures the coding parameters:
MPEG2 or mPEG4 LAyER2.
f) Locate and select the option ASPECt
RAtIO. The possible aspect ratio values
are 1:1, 4:3 and 16:9.
g) Locate and select the option BItRAtE.
The unit can be congured for a data cod-
ing speed at input of 3 to 8 mBItS/S.
NOTE
If you keep pressing the control button down you will access the information and
conguration of the following input signals.
Configuration of the carrier services
2) Locate and select the option SERVICES.
a) Locate and select the option CH1 VIDEO
AuDIO. Activate (ON) or deactivate (OFF)
the video and audio signals of the rst
input.
b) Locate and select CH1 LCN. Congure the
LCN value of the signal.
c) Locate and select CH1 NAmE. Assign a
name to the signal in CH1.
NOTE
If you keep pressing the control button down you will access the information and
conguration of the following input signals.
Configuration of the output signal
NOTE
To introduce a sequence of digits in the display move the control button verti-
cally to change the value of the current digit and horizontally to move between
digits.
NOTE
Position the cursor to the right of the current value and move the control button
vertically to increase or decrease the current value. Hold the control button up or
down to increase or decrease the current value more quickly.
3) Locate and select the option OutPut.
EN