User Guide MAC 401 REF.
Contents 4 General safety instructions 4 Types of notices 5 Basic safety instructions 6 Introduction 6 General description 6 Main features 7 General use of the unit 9 Unit installation and configuration 9 Installation 9 Power supply connection 10 Cascade installation 11 Fast menu guide 12 Main menu 19 Advanced configuration of the unit 19 User interface via web browser 21 Maintenance 21 Unit care 21 Troubleshooting 22 Technical specifications 22 MAC 401 model 23 Warr
General safety instructions/Basic safety instructions General safety instructions JJ Read all of this user manual carefully before plugging in the unit. JJ Always have these instructions to hand during installation. JJ Follow all of the instructions and safety notices regarding unit handling. Basic safety instructions DANGER of DEATH OR INJURY The meaning of the safety notices used in this manual are described below.
Introduction/General use of the unit Introduction JJ General description KEY MPEG2 and MPEG4 Layer II coding. FF RF DVB-T output, compatible with TDT. RF output, adjustable in VHF and UHF bands. Front panel with cluster map FF Loopthrough for combination of additional RF TV signals. 3 Display (LCD) 4 Control button 5 AV input 1 6 AV input 2 7 AV input 3 8 AV input 4 9 Ethernet connector JJ Dimensions: 302 mm x 251 mm x 44 mm JJ Weight: 1.
Introduction/General use of the unit Installation RISK OF damage to the unit ATTENTION NOTE Keep the button pressed up or down to browse or to modify values more quickly. 1 1) Fit and tighten the bolts and plugs securing the unit to the wall. 2) Connect AV1 to AV2 in the respective RCA connectors. 3) You can also connect the coaxial cable from the RF loopthrough input (connector F). 4) Connect the coaxial cable from the output to the unit (connector F).
Unit installation and configuration/Cascade installation Unit installation and configuration/Fast menu guide Cascade installation Fast menu guide EN The MAC 401 unit has a maximum capacity to include 4 AV analogue TV signals at the RF VHF/UHF output, coded as COFDM Digital TV signals. To increase this capacity, several MAC 401 units can be cascade connected. The maximum capacity of a group of N units is 2xN TV signals included.
Unit installation and configuration/Main menu Unit installation and configuration/Main menu Main menu b) Locate and select the option IP address. Enter the 12-digit sequence corresponding to the static IP address of the unit. c) Locate and select the option IP mask. Enter the 12-digit sequence corresponding to the IP mask of the unit. d) Locate and select the option Gateway. Enter the 12-digit sequence corresponding to the IP direction of the LAN gateway.
Unit installation and configuration/Main menu Unit installation and configuration/Main menu Restoring factory settings 6) g) Locate and select the option Factory settings to restore the factory settings of the unit. Locate and select the option BITRATE. The unit can be configured for a data coding speed at input of 3 to 8 mbits/s. EN note Select the option delete to delete all the modifications entered in the configuration by the installer or operator of the unit.
Unit installation and configuration/Main menu Unit installation and configuration/Main menu a) Locate and select the option Frequency. Configure the output frequency value between 45 MHz and 865 MHz. b) Locate and indicate output bitrate. The unit displays the output data speed in mbits/s. b) Locate and select the option Attenuation. Select the output attenuation between 0 and 47 dB. c) c) Locate and select the option OFDM mode. Select the OFDM mode between 2k and 8k subcarriers.
Unit installation and configuration/Main menu 2) Enter the unblocking code assigned by the unit operator through the web interface. 3) The unit displays the validity of the code. Advanced configuration of the unit EN User interface via web browser The web interface allows you to fully configure the MAC 401 unit through an Ethernet connection and a web browser. note NOTE The unit will remain unblocked until it is restarted or the operator deactivates the block from the web interface.
Advanced configuration of the unit/User interface via web browser This IP address may not be modified by the user. 4) 5) Press ENTER to access to the welcome screen. Maintenance Unit care Enter the user name “Admin” and the password “admin”. HANDLING THE INSIDE OF THE UNIT IS FORBIDDEN Do not dismantle or try to repair the unit, its accessories or its components. This will render the warranty null and void.
Technical specifications Warranty MAC 401 model Notwithstanding any complaints made to the direct vendor of the product, IKUSI offers unit users a two-year warranty as of the invoice date, which shall become valid on presenting the receipt of purchase.
Unit recycling Recycling of electrical and electronic equipment (Applicable in the European Union and in European countries with selective waste collection systems.) This symbol on your unit or its packaging indicates that this product cannot be treated as general domestic waste and must be handed in at the corresponding point of collection for electric and electronic equipment.
Ángel Iglesias, S.A. Paseo Miramón, 170 20009 San Sebastián, Spain Tel. +34 943 44 88 00 Fax +34 943 44 88 20 ikusi@ikusi.com www.ikusi.