Specifications

Status: Released
Version:2.2
Document: ITS-AVS Audio Visual Standards
V2.2Issued.docx
Author: Dean McFadden
Save Date: 25/08/2014
Page 28 of 63
2.13.7 Display mounting
LCD panels shall be installed on a University approved secure mounting bracket. The bracket should be
purpose designed to suit the mounting orientation (landscape, portrait, tilt, swivel, wall or ceiling mounted).
When ceiling mounting displays, the bracket must be coordinated with other services to ensure utilities such as
sprinkler systems, mechanical ducts and light fittings do not interfere with the operation of the display.
When mounting to walls the AV Integrator is to ensure that there are sufficient studs or noggins to allow for
secure mounting of the display and that the wall is able support weight of the panel and any additional loads
such as people leaning on or against the display.
2.13.8 Projector settings
As a minimum the integrator must configure all projectors for the following functionality:
a) Projector background when no image or mute mode set to black
b) All onscreen display functionality is disabled
c) Internal speaker is muted
d) Projector image is muted during “soft off
e) All external buttons and controls are disabled to prevent unauthorised access. Lockout password is
to be 1988, if this is not available then the integrator is to nominate. All password and lockout
procedures are to be documented in the appropriate column on the equipment schedule. Where
the projector buttons cannot be lockout all functional settings must be reinstated by the control
system at power up to ensure the projector will operate correctly after any unauthorised changes
2.13.9 LCD Panel settings
As a minimum the integrator must configure all projectors for the following functionality:
a) Internal fans are set to auto
b) All onscreen display functionality is disabled where possible
c) Internal speaker is operational
d) All external buttons and controls are disabled to prevent unauthorised access. Lockout password is
to be 1988, if this is not available then the integrator is to nominate. All password and lockout
procedures are to be documented in the appropriate column on the equipment schedule. Where
the projector buttons cannot be lockout all functional settings must be reinstated by the control
system at power up to ensure the projector will operate correctly after any unauthorised changes
2.13.10 Aspect ratio
All projectors used in this facility shall have native widescreen resolution of 16:10 with a resolution of either
WXGA (1280x800) or WUXGA (1920x1200). LCD/LED panels shall be FHD (1920x1080). All displays shall
truly reproduce incoming signals in their correct aspect regardless of the display’s native aspect ratio. This
should be achieved through control system programming, with users selecting correct aspect by an intuitive
interface.
Any resolution or aspect that differs from the above shall be approved by the principle i.e: 17:10 5120x2880
UHD+
For permanently installed equipment (DVD, PC etc) the default aspect ratio shall be predetermined and no
option presented to the user unless specified.