Specifications
Status: Released
Version:2.2
Document: ITS-AVS Audio Visual Standards
V2.2Issued.docx
Author: Dean McFadden
Save Date: 25/08/2014
Page 22 of 63
2.11 Power & Lighting
2.11.1 Power distribution and control
Where indicated on the schematics, distributed power within equipment racks shall be controlled by means of a
network based, rack mounted, power distribution unit. Double-adaptors and single-pole switched power strips
must not be used. AV integrators must size the power strip to suit the rack and number of devices connected. A
provision for 20% expansion must also be provided. Power strips shall be protected by accessible circuit
breakers (10A on normal circuits).
Unless otherwise specified, provide switching of powered devices as follows:
a) Un-switched remote equipment (local GPO power)
! Projectors and other display devices
b) Un-switched rack equipment (power distribution unit in rack)
! Control system
! Installed PC
! Teleconference interface and Videoconference codec
! DSPs (if required for hearing augmentation).
! Any items of equipment required to ensure that the boundary microphone is active for
hearing augmentation whilst the AV system is shutdown.
! Hearing loop amplifier
c) Instant switched rack equipment. Equipment is immediately powered when AV system is activated.
(power distribution unit in rack)
! Document camera
! Blu-ray Player/DVD
! MATV or IPTV receiver
! Matrix switches (if not integrated with control system or used for hearing augmentation).
d) Delayed switched rack equipment.
! Audio amplifiers
o Are to be energised 5 seconds after all other audio equipment
o Are to be de-energised 5 seconds before all other audio equipment
Shorten power cables to an appropriate length and terminate in Australian-standard side-entry mains plug-tops
similar to Clipsal 418S or IEC style connectors.
All outlets must be clearly labeled on the control system technical page to allow for power cycling of individual
units.
2.11.2 Power Cable Test & Tagging
All power cables supplied are required to be tested and tagged to the AS 3760 standard. A copy of the register
of cables shall be supplied as part of documentation package.