User`s manual

MP-202 Telephone Adapter 120 Document #: LTRT-50605
User's Manual
7. Define a new network bridge. Define a network bridge by checking the check boxes of
LAN Ethernet and WAN Ethernet 3 (VLAN Interface 300) in the screen 'Network
Bridging' under 'Bridged Connections' (refer to the figure below).
Figure 10-35: Network Bridging
8. Set the bridge to use 'No IP Address'. Click Apply and OK and then click OK again.
Figure 10-36: No IP Address
9. Reboot the MP-202 (optional).
10. Ensure that the PC is connected to the LAN port of the MP-202 and then configure it
to 'Obtain IP Address Automatically'; all data from the LAN port will be in VLAN 300.
11. To access the web from the WAN, you must be in VLAN 400 and use the VLAN 400
IP address.