Exiting Priming Mode
The system will automatically enter the normal heating and ltering at the end of the priming
mode, which lasts 4-5 minutes. You can manually exit Priming Mode by pressing the “Exit”
button on the Priming Mode Screen. Note that if you do not manually exit the priming mode as
described above, the priming mode will be automatically terminated after 4-5 minutes.
Be sure that the pump(s) have been primed by this time. Once the system has exited Priming
Mode, the top-side panel will display the Main Screen, but the display will not show the
temperature yet, as shown below. This is because the system requires approximately 1 minute of
water owing through the heater to determine the water temperature and display it.
– – –°F – – –°C
FILL IT UP!
Pumps
On the Spa Screen, select a “Jets” button once to turn the pump on or o, and to shift between
low- and high-speeds if equipped. If left running, the pump will turn o after a time-out period.
Non-Circ Systems
The low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready
Mode (See page 9), Pump 1 low may also activate for at least 1 minute every 30 minutes to detect
the spa temperature (polling) and then to heat to the set temperature if needed. When the low-
speed turns on automatically, it cannot be deactivated from the panel, however the high speed
may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, the circ pump operates continuously (24 hours) with
the exception of turning o for 30 minutes at a time when the water temperature reaches 3°F
(1.5°C) above the set temperature