Owner`s manual

30
Owners Manual
English
Preparation and Filling
Fill the spa to its correct operating level (6”/15.5cm below the top of the the spa). Be sure to open
all valves and jets in the plumbing system before lling to allow as much air as possible to escape
from the plumbing and the control system during the lling process. After turning the power on
at the main power panel, the top-side panel will display a splash screen or startup screen.
Priming Mode – M019*
After the initial start-up sequence, the control will enter Priming Mode and display a Priming
Mode screen. Only pump icons appear on the priming mode screen. During the priming mode,
the heater is disabled to allow the priming process to be completed without the possibility of
energizing the heater under low-ow or no-ow conditions. Nothing comes on automatically,
but the pump(s) can be energized by selecting the Jet” buttons. If the spa has a Circ Pump, it can
be turned on and o by pressing the “Circ Pump button during Priming Mode.
Priming the Pumps
As soon as the Priming Mode screeen appears
on the panel, select the Jets 1” button once to
start Pump 1 in low-speed and then again to
switch to high-speed. Also, select the other
pumps, to turn them on. The pumps should be
running in high-speed to facilitate priming. If
the pumps have not primed after 2 minutes,
and water is not owing from the jets in the
spa, do not allow the pumps to continue to run.
Turn o the pumps and repeat the process.
Note: Turning the power o and back on again
will initiate a new pump priming session.
Sometimes momentarily turning the pump o
and on will help it to prime. Do not do this
more than 5 times. If the pump(s) will not
prime, shut o the power to the spa and
call for service.
Important: A pump should not be allowed to run without priming for more than 2 minutes.
Under NO circumstances should a pump be allowed to run without priming beyond the end
of the 4-5 minute priming mode. Doing so may cause damage to the pump and cause the
system to energize the heater and go into an overheat condition.
FILL IT UP!