Owner`s manual
25
Operation
and 6 hours each cycle (12 hours per day) for circ pump
models. Filter cycle start and end times, as well as lter cycle
duration can be custom programmed by the spa owner.
Custom Filter Cycles:
Note: To ensure adequate water ltering, Bullfrog recommends
that custom lter cycles be at least 2 hours twice per day for
non-circ pump models and 6 hours twice a day for circ pump
equipped models. Bullfrog also recommends lter cycles be
programmed to begin 12 hours apart, as two 2 hour lter cycles
12 hours apart is better than one 4 hour lter cycle in a day.
Since Bullfrog Spas are so well insulated, programming the lter
pump to operate for extended periods of time with the cover on
the spa will result in a rise of the spa water temperature. During
warmer months of the year, it is advisable to set the duration of
the ltration cycle to the minimum level needed to keep the
water clean.
To program custom lter cycle settings, press time + mode/prog
+ mode/prog + mode/prog within 3 seconds. The PROGRAM,
FILTER 1, and START TIME icons will appear on the display. Press
warmer or cooler to choose lter cycle 1 start time hour. Press
mode/prog to save the hour. Press warmer or cooler to choose
the lter 1 start time minutes. Each press changes the start time
by 5 minutes. Press mode/prog to enter the minutes. Press mode/
prog to see the PROGRAM, FILTER 1, and END TIME icons. Adjust
the lter 1 cycle end time hour and minutes as outlined above
using the warmer or cooler and mode/prog buttons. Next press
mode/prog to see the PROGRAM, FILTER 2, and START TIME icons.
Proceed as outlined above to enter the lter 2 start and end
times. After the lter 2 end time is entered, press mode/prog to
conrm the new lter cycle times into the system and display the
current water temperature. Press time at any time during lter
cycle programming sequence to save the values entered up to
that point and exit programming.
Jets 1
Press jets 1 to turn pump 1 on and off and to shift between low
and high speeds. If left running, the low speed will automatically
turn off after 2 hours and the high speed will turn off after 30
minutes. In non-circ pump spas, pump 1 turns on in low speed
automatically during lter cycles, and it cannot be turned off
with the control panel jets 1 switch.
NOTE: When in standard mode, the lter pump (either pump 1-
low speed or optional circ pump) will activate for at least 2
minutes every 30 minutes to detect the spa temperature and
will heat to set temperature (if needed).
Jets 2 (optional)
If your spa is equipped with a two jet pump system, press jets 2
to turn pump 2 on or off and to shift between low and high
speeds. If left running, the pump will turn off automatically after
30 minutes.
NOTE: If the spa does not have two pumps, the jets 2 button will
be labeled aux on the control pad.
Auxiliary Jet(s) Control
An optional auxiliary control pad(s) on the side of the spa can
also activate the pump(s). NOTE: This option is not available on
Series II Hot Tub models.
Light
Press light to toggle the light on and off. The light will turn off
automatically after 4 hours.
LED Light (optional)
Press light button to turn the LED light on and off. To toggle
between all the LED color options, press the light button on,
then off, then wait about 1 second and turn on again. A
different color option will appear. The LED light will turn off
automatically after 4 hours.
Option
This button does nothing by itself; however, it is used as part of
the Invert sequence described below.
Invert Display
Press warmer or cooler + option to change the orientation of the
LED display.
Freeze Protection
If the temperature drops to 44°F (7°C) within the heater, the
pump automatically activates to provide freeze protection.
The pump will stay on 4 minutes after the sensor has detected
the temperature has reached 45°F (7°C) or higher.
Locking the Control Panel
Press time + jets 1 + warmer within 3 seconds to lock the control
pad. When locked, the Panel Lock (PL) indicator light will light.
All buttons will be frozen except the time button. To unlock the
panel, press time + jets 1 + cooler.
Locking the Set Temperature
Press warmer or cooler + time + jets 1 + warmer within 3 seconds
to activate the lock. The TL indicator light will light when the set
temperature is locked. To unlock the set temperature, press
warmer or cooler + time + jets 1 + cooler.
*Ozone Purier (optional)
The ozone purier runs during lter cycles. The ozone is disabled
during spa use by either turning pump 1 to high speed or pump
2 to high or low speed (for non-circ spas), or, for a circ pump
spa, by turning pump 1 or pump 2 on at any speed.