Owner`s manual
11
Installation and Setup
Electrical Requirements  
and Installation Instructions 
IMPORTANT: Provide a copy of these instructions 
to your Electrician.
INTRODUCTION 
The installation of all spas must be in accordance with 
national and local wiring rules. Always have a licensed 
Electrician perform the electrical installation. Each Bullfrog 
Spa is manufactured and tested to a standard that provides 
maximum protection against electrical shock. Improper 
wiring may prevent the spa from operating safely which 
could result in electrical shock, injury or death. Improper 
wiring could also lead to a malfunction of the spa’s 
equipment and risk of re.
Important Technical Information 
Voltage Denitions: When reading these instructions, the term 
120V~ refers to the 110-120V~ range of voltage, while the 
230V~ term refers to the 220-240 range of voltage.
Wiring Connection: Appliance must be permanently 
connected to xed wiring (except for U.S./CAN 120V~/60Hz 
Cord-Connected units).
Wiring Diagrams: In addition to the instructions that follow, 
please reference the appropriate Wiring Diagrams (120V~/
60Hz Cord-Connected, 120V~/60Hz Permanently-Connected, 
230V~/60Hz Permanently-Connected, or 230V~/50Hz 
Permanently-Connected).
Electrical Service Wire Size and Type: The size of wire 
required to supply the spa with power is dependent upon the 
length of the electrical run and should only be determined by 
a licensed Electrician. Installation must be in accordance 
with all national and local wiring rules. All wiring must be 
copper to ensure adequate connections. Never use 
aluminum wire.
Spa Location:
Overhead Power Lines: Based upon the national and local 
wiring rules that apply to your area, you will need to install 
your spa at the required minimum horizontal and vertical 
distances from all power lines.
Service Disconnect: Based upon your area, a disconnect 
device must be incorporated into the xed wiring in 
accordance with national and local wiring rules. If the 
national and local wiring rules permit, a GFCI Sub-Panel 
may be used to substitute the service disconnect, providing 
that it is located within the same parameters.
•
•
Electrical Outlets, Switches and Devices: Based upon the 
national and local wiring rules that apply to your area, you 
must install your spa at or beyond the required minimum 
distance from all electrical outlets, switches, and devices.
Bonding: Based upon the national and local wiring rules that 
apply to your area, the Control System Box located inside 
the equipment compartment of your spa must be bonded 
to all metal equipment, handrails, xtures, enclosures, pipe, 
or conduit that are located within the maximum specied 
distances. The bonding is to be connected to the ground lug 
connector on the exterior surface of the Control System Box 
and all metal items previously described.
Equipment Compartment Access: Make sure the spa is 
positioned so that access to the equipment compartment 
will not be blocked.
Ground Fault Circuit Interrupters (GFCI): As per national and 
local wiring rules, all spas, hot tubs, and associated electrical 
components must be protected by a GFCI, either at the main 
breaker box or at the service disconnect. 
WARNING: Removal or bypassing the GFCI will result in an 
unsafe spa and will void your spa’s warranty. When installing 
the GFCI, all conductors except the green ground must be 
routed through the GFCI, including the neutral. Never bypass 
the neutral line. If the neutral line is bypassed, then the 
current will be imbalanced and cause the GFCI to trip. See 
GFCI Wiring Diagrams or contact Bullfrog International, LC or 
your authorized Bullfrog Spa dealer. REQUIRED TEST 
PROCEDURE: After the spa is rst lled and turned on, and 
prior to each use, the GFCI should be tested as follows:  
Step 1 press Test on the GFCI breaker. The spa should stop 
operating. Step 2 after 30 seconds, press Reset and then 
verify that power has been restored to the spa. If the GFCI 
fails to operate in this manner you may have an electrical 
malfunction and be at risk of electrical shock. Should this 
occur, turn off the GFCI breaker to the spa and do not use 
the spa until the malfunction has been repaired by a licensed 
Electrician or your authorized Bullfrog Spa dealer.
Dedicated Electrical Circuit Breaker: The electrical service to 
the spa must include a suitably rated switch or circuit breaker. 
Whether the spa is a 120V~/60Hz Cord-Connected spa or a 
120V~/60Hz, 230V~/60Hz or 230V~/50Hz Permanently-
Connected spa, it is required that the circuit breaker that 
supplies power to the spa is dedicated and does not supply 
power to any other electrical outlet, device or item.
Electrical Access Conduit: Each Bullfrog Spa is manufactured 
with an electrical access conduit which allows the electrical 
•
•
•
Master Control Pad 
JetPak
™
Ozone Jet 
Headrest 
SnapCap
™
Foot Jets 
Suction Fitting 
Floor Drain 
Auxiliary Control Pad 
(optional) 
Auxiliary Control Pad 
(optional) 
Cup Holder 
Cup Holder 
Light 
FilterCap
™ 
Filter Weir Door
Equipment Compartment 
(Drain Hose and Product 
Specifications Inside) 