Installation and Setup
Electrical Requirements
and Installation Instructions
IMPORTANT: Provide a copy of these instructions
to your Electrician.
INTRODUCTION
The installation of all spas must be in accordance with
national and local wiring rules. Always have a licensed
Electrician perform the electrical installation. Each Bullfrog
Spa is manufactured and tested to a standard that provides
maximum protection against electrical shock. Improper
wiring may prevent the spa from operating safely which
could result in electrical shock, injury or death. Improper
wiring could also lead to a malfunction of the spa’s
equipment and risk of re.
Important Technical Information
Voltage Denitions: When reading these instructions, the term
120V~ refers to the 110-120V~ range of voltage, while the
230V~ term refers to the 220-240 range of voltage.
Wiring Connection: Appliance must be permanently
connected toxed wiring (except for U.S./CAN 120V~/60Hz
Cord-Connected units).
Wiring Diagrams: In addition to the instructions that follow,
please reference the appropriate Wiring Diagrams (120V~/
60Hz Cord-Connected, 120V~/60Hz Permanently-Connected,
230V~/60Hz Permanently-Connected, or 230V~/50Hz
Permanently-Connected).
Electrical Service Wire Size and Type: The size of wire
required to supply the spa with power is dependent upon the
length of the electrical run and should only be determined by
a licensed Electrician. Installation must be in accordance
with all national and local wiring rules. All wiring must be
copper to ensure adequate connections. Never use
aluminum wire.
Spa Location:
Overhead Power Lines: Based upon the national and local
wiring rules that apply to your area, you will need to install
your spa at the required minimum horizontal and vertical
distances from all power lines.
Service Disconnect: Based upon your area, a disconnect
device must be incorporated into the xed wiring in
accordance with national and local wiring rules. If the
national and local wiring rules permit, a GFCI Sub-Panel
may be used to substitute the service disconnect, providing
that it is located within the same parameters.
Electrical Outlets, Switches and Devices: Based upon the
national and local wiring rules that apply to your area, you
must install your spa at or beyond the required minimum
distance from all electrical outlets, switches, and devices.
Bonding: Based upon the national and local wiring rules that
apply to your area, the Control System Box located inside
the equipment compartment of your spa must be bonded
to all metal equipment, handrails, xtures, enclosures, pipe,
or conduit that are located within the maximum specied
distances. The bonding is to be connected to the ground lug
connector on the exterior surface of the Control System Box
and all metal items previously described.
Equipment Compartment Access: Make sure the spa is
positioned so that access to the equipment compartment
will not be blocked.
Ground Fault Circuit Interrupters (GFCI): As per national and
local wiring rules, all spas, hot tubs, and associated electrical
components must be protected by a GFCI, either at the main
breaker box or at the service disconnect.
WARNING: Removal or bypassing the GFCI will result in an
unsafe spa and will void your spa’s warranty. When installing
the GFCI, all conductors except the green ground must be
routed through the GFCI, including the neutral. Never bypass
the neutral line. If the neutral line is bypassed, then the
current will be imbalanced and cause the GFCI to trip. See
GFCI Wiring Diagrams or contact Bullfrog International, LC or
your authorized Bullfrog Spa dealer. REQUIRED TEST
PROCEDURE: After the spa is rst lled and turned on, and
prior to each use, the GFCI should be tested as follows:
Step 1 press Test on the GFCI breaker. The spa should stop
operating. Step 2 after 30 seconds, press Reset and then
verify that power has been restored to the spa. If the GFCI
fails to operate in this manner you may have an electrical
malfunction and be at risk of electrical shock. Should this
occur, turn off the GFCI breaker to the spa and do not use
the spa until the malfunction has been repaired by a licensed
Electrician or your authorized Bullfrog Spa dealer.
Dedicated Electrical Circuit Breaker: The electrical service to
the spa must include a suitably rated switch or circuit breaker.
Whether the spa is a 120V~/60Hz Cord-Connected spa or a
120V~/60Hz, 230V~/60Hz or 230V~/50Hz Permanently-
Connected spa, it is required that the circuit breaker that
supplies power to the spa is dedicated and does not supply
power to any other electrical outlet, device or item.
Electrical Access Conduit: Each Bullfrog Spa is manufactured
with an electrical access conduit which allows the electrical
Master Control Pad
JetPak
Ozone Jet
Headrest
SnapCap
Foot Jets
Suction Fitting
Floor Drain
Auxiliary Control Pad
(optional)
Auxiliary Control Pad
(optional)
Cup Holder
Cup Holder
Light
FilterCap
Filter Weir Door
Equipment Compartment
(Drain Hose and Product
Specifications Inside)