User`s manual

26
MA Lighting Technology GmbH Höhenweg 6 D-97249 Eisingen Tel.:(49)-9306-2459
Lightcommander II User´s Manual
6.3 Output Limit
Press the PREVIEW button
First button toggles to the Limit function.
The LED´s of all channels, which got a
reduction yet, lit up. The display lists the
limitations whereas FF=100% means, that
there is no reduction on this channel.
1.
2.
LIMIT
A1
A2
A3
A4
A5
A6
43
44
45
46
47
48
37
38
39
40
41
42
31
32
33
34
35
36
25
26
27
28
29
30
19
20
21
22
23
24
13
14
15
16
17
18
07
08
09
10
11
12
01
02
03
04
05
06
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
87
87
87
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
-
62
FF
FF
FF
ALL 100 %0 % OFF100 %
3b.
or:
Sets all selected
channels to 100%
Clears the output for the
selected channel
Cancels all reductions
for all channels.
3a.
Limiting single channels:
Single channel buttons
Selecting of one or more channels. The numbers of these
channels get displayed inverted.
The encoder wheel or one of the first two display
buttons
changes all selected channels simultaneously. Limitations
work on line on the actual output.
Single channel faders of preset 2:
The reduction can also be set via the faders of preset 2. The
fader will take over control as soon as it reaches the actual
value (Grap mode). To do a limitation via preset 2 without
effect to the stage the preset 2 master has to be at zero.
The PREVIEW or QUIT button returns the board to the Top Menu. Any
limitation gets indicated by the warning "OUTPUT LIMIT".
4.
Channels with numbers displayed on black back-
ground can be altered by the encoder or the first two
display buttons