Vi Changing Procedures < From L-Port to M-Port >
The position L-Port
Remove the Variable Vi guide pin from the
bottom of the suction cover.
Turn the capacity control handle 4 7/8 times
in counter-clockwise and remove the set
bolt from the bottom of the rotor casing.
Replace it with Variable Vi guide pin.
Screw the Variable Vi guide pin into the
bottom of the rotor casing. If it is tight, turn
the capacity control handle slightly in both
directions.
Lock the set bolt into the bottom of the
suction cover.
This completes the procedures for
changing to the M Port.