Operation Manual
204
CONNECTING THE FEEDER
CABLE
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield A behind the cooker.
– Open completely the cable clamp D.
– Position the U bolts onto terminal block
B (fig. 10.1) according to the diagram
in fig. 10.2a, 10.2b, 10.2c.
– Insert the feeder cable into the cable
clamp D. The supply cable must be
of a suitable size (see the section
“Feeder cable section”).
– Connect the phase and earth cables
to terminal B according figures 10.2a,
10.2b, 10.2c.
– Pull the feeder cable and block it with
the cable clamp D.
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cooker
it is necessary to:
– Remove the two screws that hold shield
“A” behind the cooker.
– Open completely the cable clamp “D”.
– Position the U bolts onto terminal block
“B” (fig. 9.1) according to the diagram in
figs. 9.2, 9.3.
– Insert the feeder cable into the cable
clamp “D”. The supply cable must be of
a suitable size (see the section “Feeder
cable section”).
– Connect the phase and earth cables to
terminal “B” according figures 9.2, 9.3.
– Pull the feeder cable and block it with
the cable clamp “D”.
– Re-mount shield “A”.
N.B. The earth conductor must be left
about 3 cm longer than the others.
A
D
B
Fig. 9.1
FEEDER CABLE SECTION
“TYPE H05RR-F”
230 V ac 3 x 6 mm
2
(**)
400 V 3N ac 5 x 2,5 mm
2
(**)
400 V 2N ac 4 x 6 mm
2
(**)
(**) Connection with wall box connection.
– Diversity factor applied.
– A diversity factor may be applied to the
total loading of the appliance only by a
suitablyqualiedperson.