BUBBLE SPA B110 BLUE SEA A081023(EU)/A081024(UK) B130 CAMARO A081012(EU)/A081013(UK) B140 ELEGANCE A081004(EU)/A081002(UK) A081003(EU)/A081001(UK) DO NOT RETURN MERCHANDISE DIRECTLY TO STORE. PLEASE CALL OUR AFTER SALES SERVICE CENTER FOR HELP OR EMAIL US AT info@the-mspa.
SAFETY INSTRUCTIONS WARNING When installing and using this electrical equipment, basic safety precaution should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS. WARNING: RISK OF ELECTRIC SHOCK. Insert the plug only to a properly grounded socket. WARNING: The spa must be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
DANGER: Risk of accidental drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children can not use this spa unless they are supervised at all times. WARNING: RISK OF ELECTRIC SHOCK. Install at least 1.5m from all metal surfaces. WARNING: RISK OF ELECTRIC SHOCK. Never operate any electrical appliance when in your spa or when your body is wet. Never place any electric appliance, such as a light, telephone, radio, or television, within 1.
CAUTION: People with infectious diseases should not use a spa. CAUTION: Do not use the spa immediately following strenuous exercise. CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are slippery. CAUTION: To avoid damage to the pump, the spa must never be operated unless the spa is filled with water. CAUTION: Immediately leave spa if uncomfortable or sleepy. CAUTION: Never add water to chemicals.
INSTALLATON INSTRUCTIONS NOTE: Ensure to check all parts are present. A: Synthetic leather with foil and zipper A. B. C. D. E. ) G. H. , J. K. B: Control panel C: Spa pool D: Test strip E: Digital lock F: Inflation Hose G: Filter cartridge H: Drainage hose I: Repair kit J:Barometer K:Inflatable bladder www.the-mspa.ca A. Site Requirements WARNING: The floor has to be capable of supporting the expected load. WARNING: An adequate drainage system has to be provided to deal with overflow water.
is level so the spa sits stably and properly. During filling, emptying or when in use, water may spill out of the Spa. Therefore the spa should be installed near a ground drain. Do not leave the Spa’s surface exposed to direct sunlight for long periods of time. B. RCD Test WARNING: RISK OF ELECTRIC SHOCK. The RCD plug must be tested before each use. WARNING: Insert the RCD plug into a residual current device (RCD) protected power receptacle only.
b) c) d) b)Screw the control panel onto the spa, fasten the ring to the pipe adaptor. c)Connect the connectors. Make sure that the mark of each connector are properly matched together d)Open the air valve under the control panel. Screw one end of inflation hose onto it e) Unscrew the top part of air valve on the Spa. Connect the other end of inflation hose into the valve. f) As previously outlined, test spa’s RCD plug. g) Inflate the spa pool by pressing the “bubble” button.
air leakage and even the broken of the spa pool. Please pull out the barometer and then unscrew bottom part of the air valve, let some air out. Check it again with barometer, till the pin points to the green area. Note: 1) It is imperative that you test the air pressure inside the spa pool. Over inflated spa together with filled water pressure and sunshine will make the air pressure even bigger. 2) Never over inflate your spa. Valve air pressure inside the pool is tested to be ③.
How to change the combination of digital lock: 1) Original combination is set as 000 2) Push release button (c) (a) (a) in the direction of the arrow shown and the lock will be released. 3) Set your desired combination by move the number wheel. (b) Please do not forget your new combination. (1) (2) (3) 4) Insert back the steel cable to its end in the direction of the arrow. The new combination is ready for use. WARNING: Do not move the number wheels while the digital lock is open.
Water Filtration Button: This button turns the Filter Pump on and off. The light of the water filtration button displays green when the filtration system is activated. Heat Button: Use this button to activate the heating system. The heater does not stop heating the Spa until the current water temperature reaches 1°C higher than the setting temperature. Then only the “heater” button is on. After the current water temperature drops 2°C below the set point temperature the heating system will restart.
mains soiled and discolored the Filter Cartridge should be replaced . 4. Put on the filter cartridge cover and place the filter cartridge to water inlet by turning it clockwise Drainage 1. Turn off all the buttons on the control panel. 2. Unscrew the valve on outside of the spa pool till it is detached from the on the drainage structure. 3. Connect the black drainage hose on to the drainage structure. Make sure it is well connected and the other end of the drainage hose is connected to a ground drain.
If the Spa is torn or punctured use the provided Repair Patch. Dry the area to be repaired. apply the glue for PVC to PVC to the repair patch and then attach it onto the damaged area. Smooth the surface to remove any air bubbles. A secure unnoticeable repair can usually be made. Spa Storage After the spa is drained, unscrew the complete part of the air valve on the spa pool and the spa will be deflated. Make sure all water is drained from the Spa and control box.
Problems Control box does not operate Probable Causes Solutions -Power failure -Check power source -RCD tripped -Reset RCD/Check if the home fixed wiring too thin -RCD broken to afford 2300W. -Call for service if it does not reset.
1.5m Zone 2 2.5m 1.5m Zone 1 2.5m Zone 1 Zone 2 Zone 0 Zone 0 Zone 0 1.5m 2.0m 2.0m 1.5m NOTE - The measured zone dimensions are limited by walls and fixed partitions. Figure 702A - Zone dimensions of swimming pools and paddling pools SAFETY & ANNOUNCEMENTS a. A local supplementary equipotent bonding shall connect all extraneous conductive parts in Zones 0,1 and 2 with protective conductors of all exposed conductive parts situated in these zones; b.
chase. In order to supply the customer with the most up to date service we respectfully request the purchaser to register their purchase by completing the attached Warranty Registration Card and mail it to the manufacturer within 15 days of date of receiving the purchase, Transportation costs incurred to and from the manufacturer or authorized service center is the responsibility of the purchaser. This includes freight charges for parts shipped to your dealer or service center.