music communications system Finish-Out Instructions dmc1
dmc1 
www.mssystems.com | 800.421.1587 | www.mssystems.com 
Page 
5 
•  Do not over-tighten the screws for the remote stations or the 
master as the plastic face panels may crack or strip out. 
•  Use only M&S Systems certified replacement parts and have them 
installed by an M&S Systems dealer or installer. Unauthorized 
substitutions can result in fire, electric shock, or other hazards. 
•  Upon completion of any service or product repair, have the M&S 
Systems dealer or installer conduct a safety check to ensure the 
system is in proper operating condition. 
•  Use only a damp cloth to clean the dmc1 master and room stations. 
Do not use liquid cleaners or aerosol cleaners. 
Finish-Out Instructions 
The finish-out installation should be made after the application of wall 
covering material. 
Tools required: 
•  #2 Phillips screwdriver 
•  Standard flat head screwdriver 
•  Wire stripper/cutter 
•  Level 
Installing the Room Station  
Collect all the connectors included in the room 
station packages and place them in the wall 
housing for use later. At each room station 
location, strip approximately 4 inches of jacket 
from the CAT5 wire and separate the colored 
conductors from one another. Strip ½ inch of 
insulation from each conductor as shown in figure 1. 
Figure 1 - CAT5 wire 