User manual
8
SettingtheaddressandthemodeofoperationwiththeDIPswitches:
• SettingthemodeofoperationwithDIPSwitch10
Switch 10 off = fx (MM) / mfx
Switch 10 on = DCC
• fx(MM)/DCCSettingtheaddresswithDIPswitches(See
table starting on Page 30)
Please note: Always do settings with the DIP switches when
thereisnovoltagepresent.Thesignaldoesnotrecognizethe
currentswitchsettingsuntilthevoltageisturnedon.
Programming with the CS 2
fx (MM)
TheCVprogrammingmustbedoneontheprogrammingtrack.
Only one signal may be connected to the programming track at
a time.
ThefollowingCVscanbechangedinfx(MM):CV39,40,41,and
42.WithCVs41and42thevaluemustbedividedby4infx(MM),
becauseonlythevalues0-80areallowed,forexample:
255/4=64(rounded).
Duringtheprogrammingprocedure,thesignallightwillblink.
During programming with the Central Station, by contrast the
signalisswitched.Aftertheendoftheprogrammingprocedure,
thesignalissetat“Go”.
The signal must be activated once before programming with
theMobileStation2.Afterthat,thedesiredCVsettingscanbe
changedandattheendthesignalmustbeswitchedagain.
The procedure for programming with the 6021 Control Unit can
befoundatwww.maerklin.de->Tools&Downloads->Tech-
nischeInformationen.
Please see the operating instructions for the control devices in
questionforprogrammingwithotherdevices.
DCC
CVprogrammingmustbedoneontheprogrammingtrack.Only
one signal may be connected to the programming track at a
time.
The light on the signal will blink as a check during the data
transmission.
Please see the operating instructions for the control devices in
questionforprogrammingwithotherdevices.
CV for fx (MM) and DCC
Withfx(MM)theaddresscanbesetonlywiththeDIPswitches.
Thevaluesinparenthesesarefactorydefaultsettings.
CV Meaning Values
1 Address 1 - 255 1-255 (1) only DCC
9 Addresses 256 - 2040 0-7 (0) only DCC
39
PoM*
Slow movement 0 (0)
Medium fast movement 1
Fast movement 2
Medium fast movement
with bouncing
3
Fast movement with
bouncing
4
Medium fast movement
with bouncing of Arm 1
5 only with 70411 /
70412
Medium fast movement
with bouncing of Arm 2
6 only with 70411 /
70412