Datasheet

02 02
ngs are realized with class “H” wires (165°C)
or DIN 43650A connectors
All windi
Protection class: IP 65 (with connector) - EN 60529
Voltage tolerance: -10% ... +6% AC / ± 5% DC
Operation: continuous
Insulation class: “F” and “H” EN 60730
O G2 0202 U
N.B. SPECIAL VOLTAGE AND/OR POWERS ARE AVAILABLE UPON REQUEST AND DEPENDING ON QUANTITY: PLEASE, CONTACT OUR COMMERCIAL DEPART-
WEIGHT: Kg 0.146
25
16 32
41,5
Ø 14,7 mm
armature tube
guide hole
mm
mm
mm
COILS FOR M&M INTERNATIONAL SOLENOID VALVESCOILS FOR M&M INTERNATIONAL SOLENOID VALVES
SERIES: 7000
TECHNICAL DATA
DIMENSIONS & WEIGHTS
CODE voltage power class ambient temp. media temp. ED notes
7250
24V DC 14 W -
“F”
140°C
-20°C +50°C -20°C +130°C 100%
standard coils are
normally supplied on our
BASIC LINErange
7200
24V 50 / 60 HZ 18 VA 36 VA
7400
110V - 50 HZ 18 VA 36 VA
7600
200V - 50 HZ 18 VA 36 VA
7700
230V - 50 HZ 18 VA 36 VA
7251
24V DC 14 W -
“H”
165°C
-20°C +60°C -20°C +150°C 100%
7201
24V 50 / 60 HZ 18 VA 36 VA
7401
110V - 50 HZ 18 VA 36 VA
7601
200V - 50 HZ 18 VA 36 VA
7701
230V - 50 HZ 18 VA 36 VA
715R
12V DC 10 W -
“F”
155°C
-20°C +60°C -20°C +130°C 100%
UL approved coils
(recongnized component ,
file No E193928)
725R
24V DC 10 W -
720R
24V 50 HZ 15 VA 30 VA
726R
24V 60 HZ 15 VA 30 VA
740R
110V - 50HZ 15 VA 30 VA
760R
200V - 50HZ 15 VA 30 VA
770R
230V - 50HZ 15 VA 30 VA
standard coils are
normally supplied on our
BASIC LINErange
for high temperatures
holding
inrush min max
min
max
SELECTION TABLE