User's Manual

RWR95.50 Operation
23
2.8 Optical Indicators
2.8.1 Indicators in Bi-directional Mode
Indicator
Blinking pattern
Meaning
Status LED (1/Fig. 20)
Green
Status: "READY"
Receives signals from measurement
system
Green flashing
Activation of measurement system A/B/C
Orange
Status: "PROBE"
Measurement system deflected
Red
Inactive status of measurement system
Red flashing
Error function, refer to chapter 2.8.3
Battery LED (2/Fig. 20)
Red
Status: "LOW BATTERY"
Measurement system transmits low battery
warning
Change measurement system batteries!
Red flashing
Error function, refer to chapter 2.8.3
2.8.2 Indicators in Mono-directional Mode
Indicator
Blinking pattern
Meaning
Status LED (1/Fig. 20)
Green
Status: "READY"
Receives signals from probe
Orange
Status: "PROBE"
Measurement system deflected
Red
Inactive status of measurement system
Red flashing
Error function, refer to chapter 2.8.3
Battery LED (2/Fig. 20)
Red
Status: "LOW BATTERY"
Measurement system transmits low battery
warning
Change measurement system batteries!
Red flashing
Error function, refer to chapter 2.8.3
Fig. 20 LED Indicators of RWR95.50
1
2
Transmission power
indicator