User's Manual

RWR95.50 Operation
21
2.6.2 Mono-directional Mode
INFORMATION
Mechanical self activation of the probe.
1. Switching ON the probe:
1.1. Load probe into spindle.
1.2. Probe switches ON by mechanical ON-OFF method:
AZ → Pullforce at SK-pullstud
ME → Switch ON mechanic into HSK
WS → Cooling water supply or spindle air blast
(Description of mechanical switch ON methods in the respective operating instructions)
1.3. Probe transmits Wake-Up signal to receiver.
1.4. Receiver transmits transmission frequency to be used to probe.
1.5. Probe sends confirmation of transmission frequency and "READY" signal to receiver.
1.6. Receiver passes electrical READY signal to machine control.
1.7. Probe ready to work.
2. Switching OFF the touch probe:
2.1. Remove the probe from the spindle to switch off the probe.
Fig. 17 Activation of the measurement system in mono-directional mode
Transmission frequency
Confirmation of transmission frequency and "READY"
Activation by
spindle
Wake-Up signal to receiver
Receiver scans the frequency spectrum
for interference and evaluates frequency
bands