User's Manual

Operation RWR95.50
16
2.3 Output Signals
2.3.1 Setting the Behaviour of the Output Signals
The behaviour of the output signals is set using a rotary coding switch on the read of the device. The setting only
takes effect after a restart of the receiver.
Fig. 14 Setting of output signal with the rotary coding switch
2.3.2 Overview of Output Signal Settings
Configuration
PROBE
ERROR
LOW BATTERY
Control
All output signals Push-Pull: LOW ≤ GND+1,2 V; HIGH ≥ VDC-2 V
0*)
HIGH→LOW
HIGH→LOW
HIGH→LOW
Heidenhain/Siemens
1
HIGH→LOW
HIGH→LOW
LOW→HIGH
Fanuc Ordinary Skip / Siemens
2
HIGH→LOW
LOW→HIGH
LOW→HIGH
Fanuc Ordinary Skip / Siemens
3
LOW→HIGH
LOW→HIGH
LOW→HIGH
Fanuc Ordinary Skip / Siemens
4
LOW→HIGH
LOW→HIGH
HIGH→LOW
Fanuc Ordinary Skip / Siemens
5
LOW→HIGH
HIGH→LOW
HIGH→LOW
Fanuc Ordinary Skip / Siemens
6
LOW→HIGH
HIGH→LOW
LOW→HIGH
Fanuc Ordinary Skip / Siemens
7
HIGH→LOW
LOW→HIGH
HIGH→LOW
Fanuc Ordinary Skip / Siemens
HIGH = 3.9 V
5.4 V
8
LOW→HIGH
HIGH→LOW
HIGH→LOW
Fanuc High Speed Skip
9
HIGH→LOW
HIGH→LOW
LOW→HIGH
Fanuc High Speed Skip
A
HIGH→LOW
LOW→HIGH
LOW→HIGH
Fanuc High Speed Skip
B
LOW→HIGH
LOW→HIGH
LOW→HIGH
Fanuc High Speed Skip
C
LOW→HIGH
LOW→HIGH
HIGH→LOW
Fanuc High Speed Skip
D
HIGH→LOW
HIGH→LOW
HIGH→LOW
Fanuc High Speed Skip
E
LOW→HIGH
HIGH→LOW
LOW→HIGH
Fanuc High Speed Skip
F
HIGH→LOW
LOW→HIGH
HIGH→LOW
Fanuc High Speed Skip
*) Setting for standard delivery
Rotary coding switch S1
Set output signal