User's Manual
Radio-wave Touch Probe RWP38.41
7
O
N
OF
F
0
V
>10VD
C
<1
,
5s
<1
,
5s
M-Code
Probe ON / OFF Procedure
The bi-directional probe will be activated and deactivated by the Radio-wave Receiver RWR95.40.
After setting the M-Code the probe is activated in <1,5 s and deactivated in <1,5 s after resetting.
Mounting the Shank
Removing the shank:
Remove all „A“ and „C“ screws.
Remove shank.
Assembling the shank:
Carefully slide the shank onto the probe body. Align
the „C“ threads with the conical bores.
Insert both clamping screws „C“ and tighten lightly.
Insert adjustment screws „A“.
Align the stylus to spindle center.(see page 3)
Calibrate the probe!
Shank
Hexagon Key
A
F2mm #1097 / AF2.5mm #1346
C = Clamping Screw AF2.5mm (2x)
#1351 M=2 Nm
(
1.47 lbf.ft
)
A
= Adjustment Screw AF2mm (4x)
#135
2
M=1.5 Nm
(
1.1 lbf.ft
)
Clamping screw „C“
in conical bore
Probe
Adjustment screw „A“ in thread