1.1.3 Intended Use
The radio-wave touch probe is a partly completed machine for incorporation in machine tools or machines for
machining. It is used for measuring different workpiece geometries as well as for temperature measurement.
Any other use or any use beyond that described is not deemed to be proper. The manufacturer is not liable for any
resulting damage. The risk is borne solely by the user.
Only use the radio-wave touch probe once it has been professionally installed into the finished machine and once the
compliance of the entire machine with the EC Machinery Directive 2006/42 EC has been confirmed.
Correct use is also deemed to include reading the operating instructions as well as compliance with all information
contained in them in particular the safety instructions. Furthermore, intended use is also deemed to include all
inspection and maintenance work being carried out at the stipulated intervals.
1.1.4 Declaration of Conformity
Declarations of Conformity can be requested as required. The contact information for this purpose is listed at the end
of these operating instructions.
1.1.5 FCC- / RSS-Declaration
This device complies with Part 15 of the FCC Rules [and with Industry Canada licence-exempt RSS
standard(s)].
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the device is operated in a commercial environment. This device generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this device in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the
device shall be used in such a manner that the potential for human contact during normal operation is
minimized.
1.1.6 Validity
These operating instructions are valid for the hardware available at the date of creation of these operating
instructions. The manufacturer reserves the right to make technical modifications.
The latest version of these operating instructions can be downloaded at www.mh-inprocess.com under Downloads.
1.2 Purpose
The radio-wave touch probe IRP20.50 is used for workpiece measurement, and automatic determination and
compensation of deviating angular positions of workpieces. Moreover, it is used for setting zero points inside the
machine tool.
The radio-wave touch probe RWP20.50 is capable of measuring workpiece geometries, like edges, bores, pins, slots,
webs, angles, corners and circular arches. It is also suitable for measuring complex geometries, like three-
dimensional surfaces and for measurements involving picot axes.
In additional the radio-wave touch probe RWP20.50 can be used for measuring temperatures on workpiece surfaces.
Radio-wave transmission ensures that the measuring signals from the touch probe can be transmitted to the receiver
over large distances.