2.3 Replacing Battery
NOTICE
Risk of material damage!
Clean and dry the probe well before opening!
Do NOT blow off with compressed air!
Replace empty battery immediately!
1. Laterally pull the snap ring off from the probe (1./Fig. 10).
2. Carefully slide the battery compartment sleeve down (2./Fig. 10).
INFORMATION
The touch probe RWP20.50 is protected against wrong polarity. Therefore there is no need to pay attention to the
polarity when inserting a new battery!
3. Take the used battery out of the battery compartment and insert a new battery (3./Fig. 10).
NOTICE
Risk of material damage!
When closing the battery compartment, ensure the O-ring is properly seated!
4. Carefully slide the battery compartment sleeve upwards (4./Fig. 10).
5. Position the snap ring at the probe laterally and slide it over the probe (5./Fig. 10).
INFORMATION
After changing the battery, the time for starting the touch probe (reboot) is approx. 5 s!
Fig. 10 Battery replacement
O-ring 53.5x1.2 Viton
(1477)
Battery compartment
sleeve
Battery
(9 V, 1200 mAh, lithium)
(5677)
Snap ring
(5525)
2.
1.
3.
4.
5.