Operating Instructions

Operation RC-R-100
30
The touch probe RWP20.50-G and the laser scanner LS-R-4.8 can be activated and deactivated by the radio-wave
receiver RC-R-100. Once the M code has been set, the relevant measurement system will be activated in < 1 s* and
deactivated again < 1 s* after reset. When activating the laser scanner LS-R-4.8, an additional 10 seconds are
required to establish the WLAN connection for measurement data transmission.
The subsequent table shows the signal curves during measurement system activation in bi-directional mode:
Signal from control
Touch probe "A"
ON/OFF
to Pin 3
Touch probe "A"
RWP20.50-G
Signal from control
Touch probe "B"
ON/OFF
to Pin 3
Touch probe "B"
RWP20.50-G
* When activating the LS-R-4.8, an additional 10 seconds are required to establish the WLAN connection
Signal curves during measurement system activation in bi-directional mode
INFORMATION
The activation code set with the connection pins 7, 8 and 9 does not take effect, until the measurement system is
activated via connection pin 3. The activation code must therefore be set before activating the measurement
system!
Set the activation code of the measurement system on the receiver:
In order to establish a connection between the RC-R-100 radio-wave receiver and a measurement system
(RWP20.50-G/LS-R-4.8), the receiver must be set to the activation code of the measurement system (A-H). To do
this, the connection pins 7, 8 and 9 of the receiver must be wired according to the following table:
Measurement system activation code
A
B
C
D
E
F
G
H
Pin7 (Bit 1)
LOW
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
Pin 8 (Bit 2)
LOW
LOW
HIGH
HIGH
LOW
LOW
HIGH
HIGH
Pin 9 (Bit 3)
LOW
LOW
LOW
LOW
HIGH
HIGH
HIGH
HIGH
INFORMATION
The activation code set with the connection pins 7, 8 and 9 does not take effect, until the measurement system is
activated via connection pin 3. The activation code must therefore be set before activating the measurement
system!
The exact procedure for setting the activation code of the measurement system or for checking the existing setting is
described in the RWP20.50-G or LS-R-4.8 operating instructions.
<1 s*
<1 s*
<1 s*
<1 s*