Operating Instructions
Operation RC-R-100
26
2.3 Output Signals
2.3.1 Setting the Behaviour of the Output Signals
The behaviour of the output signals is set using a rotary coding switch on the read of the device. The setting only
takes effect after a restart of the receiver.
Setting of output signal with the rotary coding switch
2.3.2 Overview of Output Signal Settings
Configur
ation
PROBE
ERROR
LOW BATTERY
Control
0*)
HIGH→LOW
HIGH→LOW
HIGH→LOW
Heidenhain/Siemens
1
HIGH→LOW
HIGH→LOW
LOW→HIGH
Fanuc Ordinary Skip / Siemens
2
HIGH→LOW
LOW→HIGH
LOW→HIGH
Fanuc Ordinary Skip / Siemens
3
LOW→HIGH
LOW→HIGH
LOW→HIGH
Fanuc Ordinary Skip / Siemens
4
LOW→HIGH
LOW→HIGH
HIGH→LOW
Fanuc Ordinary Skip / Siemens
5
LOW→HIGH
HIGH→LOW
HIGH→LOW
Fanuc Ordinary Skip / Siemens
6
LOW→HIGH
HIGH→LOW
LOW→HIGH
Fanuc Ordinary Skip / Siemens
7
HIGH→LOW
LOW→HIGH
HIGH→LOW
Fanuc Ordinary Skip / Siemens
8
LOW→OPEN
HIGH→LOW
HIGH→LOW
Fanuc High Speed Skip
9
OPEN →LOW
HIGH→LOW
LOW→HIGH
Fanuc High Speed Skip
A
HIGH→ OPEN
LOW→HIGH
LOW→HIGH
Fanuc High Speed Skip
B
LOW→ OPEN
LOW→HIGH
LOW→HIGH
Fanuc High Speed Skip
C
LOW→ OPEN
LOW→HIGH
HIGH→LOW
Fanuc High Speed Skip
D
OPEN →LOW
HIGH→LOW
HIGH→LOW
Fanuc High Speed Skip
E
LOW→ OPEN
HIGH→LOW
LOW→HIGH
Fanuc High Speed Skip
F
OPEN →LOW
LOW→HIGH
HIGH→LOW
Fanuc High Speed Skip
*) Setting for standard delivery
Rotary coding switch S1
Set output signal