2.2.2.2 Overview of wire colours for the sensor cable
Electrical connection Single Probe versions
2.2.2.3 Output Circuit Pin 4, 5 and 6
Output Circuit Pin 4, 5 and 6
2.2.2.4 Input Circuit Pin 3, 7, 8 and 9
Input Circuit Pin 3, 7, 8 and 9
Circuit for outputs
• Pin 4 = PROBE
• Pin 5 = READY
• Pin 6 = LOW BATTERY
Low ≤ GND + 1.2 V
High ≥ VDC - 2 V
RC-R-100
Internal
Signal
VDC (Pin 1)
GND (Pin 2)
Electronic
Fuse
Input CNC
max. 40 mA
RC-R-100
Internal
Signal
VDC (Pin 1)
GND (Pin 2)
Output CNC
max. 1 mA
Circuit for inputs
• Pin 3 = Measurement system ON/OFF
• Pin 7 = Activation code Bit 1
• Pin 8 = Activation code Bit 2
• Pin 9 = Activation code Bit 3
Low < 3 V – min. GND 0 V
High > 10 V – max. 30 V
Pin
Description
Colour
1
GND 0 V*
brown
2
12-30 V*
blue
3
M code ON/OFF (Bidi) / GND 0 V (Mono)
white
4
Probe (max. 40 mA)
green
5
READY (max. 40 mA)
pink
6
LOW BATTERY (max. 40 mA)
yellow
7
Activation code Bit1 / Serial IN
black
8
Activation code Bit2 / Serial CLOCK
grey
9
Activation code Bit3
red
10
Analog output / Serial OUT
purple
11
not assigned
grey-pink
12
Signal Connection
red-blue
*The signals can be switched to Pin 1/2. The receiver can be operated with both
polarities.