11.4
Technical specications and illustrations are without
obligation, subject to modications. 08.98/11.06
T6-H1 T8-H1 V6-H1 V8-H1
Part-No. 10B1001 (a)** 10B1101 (a)** 10B1011 (a)** 10B1111 (a)**
Connector version union tee union tee straight connector straight connector
Connector dimensions 3x ø 6 mm 3x ø 8 mm 2x ø 6 mm 2x ø 8 mm
Fittings system tube connectors of stainless steel type Swagelok
Operating pressure max. 200 bar
Operating temperature max. +180 °C
Ambient temperature -25 to +60 °C
Storage temperature -25 to +80 °C
Temperature controller capillary thermostat with high temperature limiter and low temperature alarm
integrated in electrical connection box
Operating temperature adjustable from 0 to 180 °C, set at factory at 180 °C
Low temperature alarm contact alarm point ∆T 30 °C, change over contact, voltage free; contact rating 250V, 3A~, 0,25A =
Power supply 230V50Hz, 100VA **optionally 115V 60Hz (a)
Electrical connections teminals 4 mm
2
, 2x cable gland PG13
Degree of protection IP 54 EN60529
Electrical standard EN 61010, EN 60519-1
Dimensions 350 x 320 x 120 mm (w x h x d)
Weight 4,5 kg
Material of sample contacting parts stainless steel 316Ti
Mounting Wall mounting