8.11 PROBE HEATING
The probe heating type HEX5-x.08 is suitable for temperature ranges of 85°C -185°C. It consists of a heating
plate with heating cartridges and a control electronic.
For the heater type HEX5.1.08, the control electronic is mounted onto the probe. This means a range of the
ambient temperature for the probe of 0 – 50°C.
The probe heating type HEX5.2.08 is designed for an external mounting of the control unit (in Ex zone 2). For
the electrical connection, a terminal box is mounted on the probe which means an ambient temperature
range of 0 – 70°C. The externally mounted control unit can be used within an ambient temperature range of
0 – 50°C.
Technical data may be taken from the separate operating manual HEX5-x.08.
9 TECHNICAL DATA
Gas sample probe type SP3200V (up to 185 °C) SP3200 (more than 185 °C)
Part No. 20S5705 20S5700
Weather protection shield yes
Filter housing material Stainless steel 316 / 316Ti
Sealing materials Graphite, FPM Graphite
Probe flange sealing material Graphite
Pre-filter / sample tubes optional, see data sheet 2-1.1.0.6 and 2-1.1.0.8
Sample pressure max. 0,5-6 bar
Ambient temperature -20 °C to max. 200 °C depending on the temperature class
Permissible process gas temperature depending on the temperature class, however max. 200°C at the probe entry
Filter chamber volume 120 cm
3
Filter element, porosity F-3SS150= stainless steel*, 3 micron S-2K150= ceramic**, 2 micron
Sample gas outlet connection 1x 1/4“ NPTi for max. 8mm-tube connectors
Connection gas outlet at option RS 6 mm Swagelok connector
Mounting flange DN65 PN6, FormB, SS316Ti* >DN or ANSI possible**
Weight 7 kg
Option heating type HEX5 HEX5-1.08 HEX5-2.08
Part No. 20S9650 (a) 20S9655 (a)
Temperature controller integrated (on the probe) externally
Mounting controller in the Ex-zone 2 and 22
Control electronic
Power supply 240V 50/60Hz max. 800W, alternatively 120V,50/60Hz max. 830W
Electrical connection cable gland, terminal range 6-12mm, terminals max. 4mm
2
Marking
II 3 G Ex nA nC nL IIC T5 to T2,
II 3 D Ex tD A22 IP65 T75°C to T235°C
Class I, Division 2, Groups A/B/C/D, T5 - T2B